Fusing Temperature Control
• The temperature control as detailed below is provided by means of the Fusing Roller
Heater Lamp (H1) and the Fusing Pressure Roller Heater Lamp (H2).
• The surface temperature of the Fusing Roller is converted by the Thermistor (TH1) to a
corresponding electrical signal.
1. Warm-up Control
• The temperature during the warm-up cycle is set at 170
°
.
• When the temperature of the Fusing Roller reaches this set temperature, both the Fusing
Roller Heater Lamp (H1) and the Fusing Pressure Roller Heater Lamp (H2) are turned
OFF.
2. Temperature Control in Standby State
• The temperature in the standby state is set at 171
°
.
3. Temperature Control during Printing (monochrome printing)
• The temperature during printing is set as follows.
✽
Small size paper: Plain paper whose length is 226 mm or less
4. Temperature Control during Printing (color printing)
• The temperature during printing is set as follows.
✽
Small size paper: Plain paper whose length is 226 mm or less
Plain paper
Thick paper
postcards
OHP transparen-
cies
Envelopes
Small size*
Set tempera-
ture
157°
157°
157°
166°
152°
Plain paper
Thick paper
postcards
OHP transparen-
cies
Envelopes
Small size*
Set temperature
174°
174°
166°
166°
169°
180
170
160
Warm-up: approx.
180 sec.
Plain paper (color)
In Standby
Plain paper (mono-
chrome)
During Printing
4131M061AA
Summary of Contents for magicolor 2300 Series
Page 1: ...magicolor 2300 Series Service Manual 1750058 001A...
Page 6: ...6...
Page 7: ...7 SAFETY...
Page 8: ......
Page 23: ...23 GENERAL...
Page 24: ......
Page 32: ...32...
Page 33: ...33 MECHANICAL ELECTRICAL...
Page 34: ......
Page 75: ...75 DISASSEMBLY ASSEMBLY 19971...
Page 76: ......
Page 106: ...106...
Page 107: ...107 CONTROL PANEL SER VICE MODE DESCRIPTIONS...
Page 108: ......
Page 117: ...117 TROUBLESHOOT ING...
Page 118: ......
Page 128: ...128 3 Replace PWB A...
Page 139: ...139 INDEX...
Page 140: ......