134
(13) FATAL ERROR CODE 1AH: Incorrect fusing roller high temperature
(14) FATAL ERROR CODE 1BH: Disconnection at thermistor
<Remedy>
(15) FATAL ERROR CODE 21H: Malfunction of the OHP detecting sensor
<Remedy>
(16) FATAL ERROR CODE 29H: Malfunction of the EEPROM (memory counter error)
(17) FATAL ERROR CODE 2AH: Malfunction of the EEPROM (memory data error)
(18) FATAL ERROR CODE 2BH: Malfunction of the EEPROM (memory access error)
(19) FATAL ERROR CODE 2CH: Malfunction of the EEPROM (memory recognition
error)
<Remedy>
Electrical components for detection of the malfunction
Thermistor (TH1)
Master board (PWB-A)
Controller control board (PWB-P)
Step
Check
Result
Remedy
WARNING DIAGRAM
Control
signal
Location(electrical
component)
1
Is there a short circuit at TH1?
(between CN18-1 and -2 on
the thermistor)
YES
Clean TH1.
HEATER
2-D
Replace the fusing
unit.
NO
Replace PU.
Replace PWB-A
Electrical components for detection of the malfunction
OHP detecting sensor (PC3A)
Master board (PWB-A)
Controller control board (PWB-P)
Step
Remedy
Reference
page
WARNING DIAGRAM
Control signal
Location(electrical
component)
1
Check PC3A operation.
T-1
PC3_REM
5-D
2
Replace PWB-A.
-
-
-
3
Replace PWB-P.
-
-
-
Electrical components for detection of the malfunction
EEPROM
Master board (PWB-A)
Step
Remedy
Reference
page
WARNING DIAGRAM
Control signal
Location(electrical com-
ponent)
1
Replace the EEPROM.
-
-
-
2
Replace PWB-A.
-
-
-
Summary of Contents for magicolor 2300 Series
Page 1: ...magicolor 2300 Series Service Manual 1750058 001A...
Page 6: ...6...
Page 7: ...7 SAFETY...
Page 8: ......
Page 23: ...23 GENERAL...
Page 24: ......
Page 32: ...32...
Page 33: ...33 MECHANICAL ELECTRICAL...
Page 34: ......
Page 75: ...75 DISASSEMBLY ASSEMBLY 19971...
Page 76: ......
Page 106: ...106...
Page 107: ...107 CONTROL PANEL SER VICE MODE DESCRIPTIONS...
Page 108: ......
Page 117: ...117 TROUBLESHOOT ING...
Page 118: ......
Page 128: ...128 3 Replace PWB A...
Page 139: ...139 INDEX...
Page 140: ......