23
22
T
ROUBLESHOOTING
Scan type:
Moving film, fixed sensor, single-pass scan
Film type:
Negative and positive, color and monochrome
Film formats:
Mounted and unmounted 35mm film.
Scanning dimensions:
24.61 x 36.69mm (5232 x 7800 pixels)
Optical input resolution:
5400 dpi
Image sensor:
3-line primary-color CCD with 5300 pixels/line
A/D conversion:
16 bit
Color depth:
8 bit and 16 bit per color channel
Dynamic range:
4.8
Light source:
Cold cathode fluorescent tube
Focusing:
Autofocus, point AF, and manual focus
Interface:
IEEE1394 and USB 2.0 (USB 1.1 compatible)
Power consumption:
Max. 30 W
Dimensions (W x H x D):
65 x 165 x 360 mm
2.6 x 6.5 x 14.0 in
Weight (approx.):
2.5 kg / 5.5 lb
Operating environment:
10° - 35°C (50° - 95°F), 15-80% humidity without
condensation
Storage environment:
-20° - 60°C (-4° - 140°F), 15-80% humidity without
condensation
Scan times (approx.):
Please contact your dealer for information regarding installation, USB or IEEE 1394
interface recommendations, or application compatibility. If your dealer is unable to help
you, contact an authorized Minolta service facility. Please have the following
information ready when calling Minolta technical support:
1. The name and model of your computer and operating system.
2. The available application RAM and hard disk space.
3. Other connected USB, IEEE 1394, or FireWire devices.
4. DiMAGE Scan Utility version number. The version number is displayed by
placing the mouse pointer on the status bar in the main window.
5. A description of the problem.
6. Any message that appears on the screen when the problem occurs.
7. The frequency of occurrence.
Please take the time to fill in the warranty and product registration card. Technical
support, scanner software upgrades, and product information is available when the
product is registered.
Technical support
Warranty and product registration
TECHNICAL SPECIFICATIONS
Specifications are based on the latest information available at the time of printing and
are subject to change without notice.
Closing the scanner door
The front door closes automatically when the film
holder is removed. The door must be closed for the
scanner to initialize.
If the door does not close automatically, it can be
closed manually with the supplied reset tool. Insert
the tool into the hole on the side of the scanner until
the latch releases the door. Do not force the tool into
the scanner.
The reset tool can be stored in a special clip on the
front feet on the bottom of the scanner unit. Slide
the tool between the front and back retaining clips,
see illustration.
Scanning time changes according to the
preferences used. Scanning time can be longer for
negative film than positive film.
Test conditions:
Slide Mount Holder SH-M10, Color positive film, no
autoexposure, no image correction, 5400dpi 8-bit
scan.
Windows: Pentium IV 2.53 GHz, Windows XP
Professional, 1 GB RAM, 60.9 GB hard disk space,
built-in USB port, Melco IFC-ILP4 IEEE interface,
Adobe Photoshop ver. 7.0.1.
Macintosh: PowerPC G4 1 GHz, Mac OS X 10.2.1,
1 GB RAM, 70.7 GB hard disk space, Apple
FireWire port, Adobe Photoshop ver. 7.0.1.
FireWire
IEEE1394
USB 2.0
Index scan
Prescan
Scan
15 sec.
15 sec.
10 sec.
10 sec.
60 sec.
68 sec.
69 sec.
12 sec.
16 sec.
Summary of Contents for DIMAGE SCAN ELITE 5400
Page 1: ...HARDWARE MANUAL E ...