Dowel Drill
Manual
10
GENERAL
SPECIFICATION
Pneumatic Connection:
• Approved air disconnect is required to be installed in accordance to Local & National Codes.
Environmental:
• +5°C to +40°C (+41°F to +104°F)
• 50% Rh at +40°C (+104°F), (90% Rh at +20°C (+68°F))
• Altitude – 1000m (3280ft) above mean sea level
• Unit is to be disposed according to all Local and National Regulations
Transportation and Storage:
• -25°C to +55°C for 24 hours (-13°F to +131°F)
Ingress Protection:
• Protection level IP2X is provided
Sound:
• System operates at sound levels about 85dBA and 85dBC. Hearing protection is required.
pneumatic hammer:
• DO NOT force tool. Use the correct toll for your application.
• DO NOT use the machine if valve handles do not turn drill on/off.
• DO NOT make any adjustment while air is hooked up to the machine.
operation of machine:
• DO NOT overreash, keep proper footing and balance at all times.
• DO NOT wear loose clothing, or jewelry. Tie up long hair.
• DO NOT use the machine if maintenace is required.
Transportation, service and Storage:
• DO NOT use your hands to search for air leaks
• DO NOT service the machine unless you are qualified
• KEEP OIL reservior filled - run drill frequently to keep the system lubricated.
The A-1 can be configured four different ways.
There is no need to purchase extra conversion kits.
1. Two wheel on grade for more accurate drilling
2. One wheel on grade for drilling 6” (15.2cm) to corner
3. Wall configuration for zero clearance drilling
4. Vertical configuration for all vertical applications