21
Chapter 6. Machine adjustment and setting up
EN
6.3. Air flow adjustment
Tunnel 50 Twin
It is possible to adjust the air flow on the product to pack by acting on the knobs (10) and (11).
The knobs (10) regulate the air flow in the “tunnel inlet” zone whereas the knobs (11) regulate the air flow in the “tunnel
outlet” zone.
The rotation of handles (10) and (11) determines the position of the flaps (12) which drive the hot air flow into the
desired direction so to obtain the best shrinking
Tunnel 70
It is possible to adjust the air flow on the product to pack by acting on the knobs (11).
The rotation of knobs (11) determines the position of the flaps (12) which drive the hot air flow into the desired direction
so to obtain the best shrinking.