The device tree has, in addition to the “Ethernet Device” node, a “Mismatch Plugin” node. A PWR-ICE amplifier
appears under this node when the plugin detects that the plugin loaded into the amplifier is not the same as the
plugin running on the computer.
This can occur if:
You have previously synchronized the amplifier using a different plugin. (For example, you previously
synchronized with the 96k plugin but are now running the FIR plugin on your computer).
The plugins have had a major upgrade that requires an incompatible configuration format. (This happens
very infrequently).
To update an amplifier to the plugin that you are running on your computer, click on the amplifier’s name under
“Mismatch Plugin.” You will see this dialog:
Click on “Upgrade & Synchronize.” The current configuration in the plugin will be downloaded to the amplifier.
The amplifier should then re-appear under “Ethernet Device.”
Always check and if necessary reload your configurations after performing an “Upgrade &
Synchronize” operation.