3.3 Additional lift-of protection
For safety reasons, a lift-of protection has to be generally provided on vessels. This can
be constructed separately or additionally installed in the mounting kit (see Chapter
).
For this purpose, the simplest version requires the following components:
-
1× threaded bar (1)
-
3× nut (2)
-
1× washer (3)
Assembly:
-
Mount the threaded bar (1) so that it has suicient free moving space in the drill hole.
-
Lock the nuts (2) so that there is a remaining distance A* from the washer (3).
* A = 2 mm
This distance is essential to avoid force shunts.
3.4 Selecting maximum capacity
Forces exceeding the safe load limit E
lim
in the measuring direction may change the
characteristics of the load cell or damage it.
If the safe load limit E
lim
of the load cell can be exceeded, e.g. by falling loads, then
mechanical limiting in load direction is strongly recommended.
If the destructive load E
d
of the load cell is exceeded, there is danger of mechanical
destruction.
Compression load cell Inteco® PR 6203
3 Recommendations for installation
EN-8
Minebea Intec