16
Function setting mode
Measurement Mode
DIGITAL FLOW SENSOR
( INSTRUCTION MANUAL )
MF01
How to use
–
Functions instructions
Function
code
Item
Default setting
Explanation
F-08
rotR
Display rotation
rotR
Set Display Rotation.
rotR
Output selection
oFF
F-09
EEPr
Accumulated value hold selection
EEPr
To save the last accumulated flow
value every 2 or 5 minutes.
EEPr
Accumulated value hold selection
oFF
F-10
d1s
Flow sensor display mode selection
d1s
Select to display Instantaneous
Flow or Accumulated Flow Mode.
dsp
Flow sensor display mode selection
1nS
F-91
ECo
Power-Save mode selection
ECo
Select if turn on powersave
mode to reduce power consumption.
ECo
Power-Save mode selection
no
F-92
1nP
External input selection
1nP
Select for Accumulated flow rate
zero clear, Auto-Shift or Auto-Shift
zero.
1nP
External input selection
r_r
F-93
AbUS
Modbus RTU setting
AbUS
Set ID number, baud rate and
transmission format.
1d
ID number setting
1
rAt
Baud rate setting
96
(9600 Bd)
For
Transmission format setting
n81
trR
Communications protocol setting
rtU
F-94
F1nE
Fine adjustment setting
F1nE
The displayed value can be
adjusted slightly.
F1nE
Fine adjustment setting
oFF
F-95
FoUt
Forced output function
FoUt
To turn the analog ON / OFF
forcibly.
oUt1
Forced output function
oFF
oUt2
Forced output function
oFF
F-99
rESt
Reset to the default setting
rESt
Return to the factory default setting.
rSt
Reset to the default setting
oFF
Item
Explanation
Flow display
Display instantaneous flow rate.
Accumulated flow rate display
Display accumulated flow rate.
Instantaneous Flow rate zero setting
The displayed instantaneous flow rate value can be adjusted to "0".
Accumulated flow rate zero clear
The accumulated flow rate can be set to "0".
Peak value display
The maximum pressure or instantaneous flow can be detected when the power is supplied
for a period.
Bottom value display
The minimum pressure or instantaneous flow can be detected when the power is supplied
for a period.
Key lock/unlock mode
To prevent errors occurring due to unintentional changes of the set values.