Zero clear function
Function introduce
Reset function
Function introduce
Operating the Zero clear function can set
displayed pressure to zero again. Pressure
varies in different areas due to altitude
differences, so pressure zeroing must be set.
Caution:
Operate the Zero clear function after changing the outlet pressure to atmosphere pressure.
The adjustable range of the Zero clear function is 5% F.S.. When more than this range, ER5
is displayed. Please change the outlet pressure and return the setting.
Operate the Reset function can reset the
pressure linearity and switch output.
Note: Gain (Gn), Sensitivity(Sb), and Unit(Unt)
will not be reset. .
1
2
Change the sensitivity (Sb) of the MAER for
pressure fluctuation.
Caution:
Normal operation does not require the
adjustment of sensitivity.
When the sensitivity is changed to sharp, the
hunting of pressure might be occurred, and
the secondary pressure might be unstable.
And, when the sensitivity is changed to dull,
the accuracy of the set pressure might be lost.
Press /
key to adjust
Press /
key to adjust
Press key for 2 seconds or more
Operation flow
Unlocking key
- 0 -
Y E S
R s T
Y E S
S A U
Save setting and
return to RUN mode
....