42
Calibration
ACCELERATION (ACCEL)
The ACCEL setting determines the time the motor takes to ramp
to a higher speed in either direction. ACCEL is factory set for the
fastest acceleration time (full CCW).
To calibrate ACCEL:
1. Set the speed adjust potentiometer or voltage input signal for
zero speed. The motor should run at zero (or minimum)
speed.
2. Set the speed adjust potentiometer or voltage input signal to
maximum forward speed, and measure the time it takes the
motor to go from minimum to maximum speed.
3. If the time measured in step 2 is not the desired acceleration
time, turn the ACCEL trimpot CW for a slower acceleration
time, or CCW for a faster acceleration time. Repeat steps 1
through 3 until the acceleration time is correct.
250-0281.qxd 4/4/01 11:16 AM Page 42
Summary of Contents for NRGD-4Q Series
Page 9: ...vii Regenerative Drives Figure 1 Four Quadrant Operation...
Page 12: ...x Notes...
Page 15: ...3 Dimensions Figure 2 NRGD05 Series Dimensions ALL DIMENSIONS IN INCHES MILLIMETERS...
Page 16: ...4 Dimensions Figure 3 NRGD10 Series Dimensions ALL DIMENSIONS IN INCHES MILLIMETERS...
Page 17: ...5 Dimensions Figure 4 Heat Sink Dimensions for NRGD10 Series Drives...
Page 33: ...21 Installation Figure 8 Regen Dump Circuit Connections To NRGD Drives...
Page 78: ...Notes...