17
MM-PCM Series
1. Verify that no foreign conductive material is present on the
printed circuit board.
2. Ensure that switch SW501 is properly set.
Section 4. Operation
Change voltage switch settings only when the drive is
disconnected from AC line voltage. Make sure both switches are
set to their correct position. If the switches are improperly set
to a lower voltage position, the motor will not run at full voltage
and may cause damage to the transformer. If the switches are
improperly set to a higher voltage position, the motor will
overspeed, which may cause motor damage, or result in bodily
injury or loss of life.
Dangerous voltages exist on the drive when it is powered. BE
ALERT. High voltages can cause serious or fatal injury. For your
safety, use personal protective equipment (PPE) when operating
this drive.
If the motor or drive does not perform as described, disconnect
the AC line voltage immediately. Refer to the Troubleshooting
section, page 40, for further assistance.
!
WARNING!
Before Applying Power