5.1
P.3
5.1 Changing the Joints
R.1.0
2. Release the knob of fitting
φ
2, and remove the
fitting assy for
UISS
.
3. Attach the
F seal rubber 300
removed in the procedure 2 and
the new
Fitting
to the 3-ways fitting.
4. Attach the
Cap-outer
to the Fitting.
5. Return the
cartridge rear cover
to the original location, and
affix using the screws.
F seal rubber 300
Fitting
Fitting assy
for UISS
3-ways fitting
Pay attention not to lose the F seal rubber 300.
3-ways fitting
F seal rubber 300
Fitting
Cap-outer
Attach it so that the step of F seal rubber 300 is at
the side of the 3-ways fitting.
Be sure not to insert the fitting obliquely.
Be sure to confirm that the hook of the fitting is
hanging on the 3-way fitting.