4
—— Center of Spot
– – – Laser pointer (approx. 19mm above center of spot)
Spot size at distance indicated
c:b ≈ 12:1
a
b
3
=Ø125mm
C
3
=Ø1,5m
C
2
=Ø1m
C
1
=Ø0,5m
b
3
=Ø83mm
b
1
=Ø41mm
warning
Never connect the Tem-
perature Probe to an energized circuit.
mainTenance
warning
To reduce the risk of per-
sonal injury and damage, never immerse
your tool in liquid or allow a liquid to flow
inside it.
warning
To reduce the risk of injury,
always remove the batteries from the tool
before performing any maintenance. Never
disassemble the tool. Contact a
milwaukee
service facility for ALL repairs.
Cleaning
Clean dust and debris from tool. Keep tool handles
clean, dry and free of oil or grease. Use only mild
soap and a damp cloth to clean the tool since certain
cleaning agents and solvents are harmful to plastics
and other insulated parts. Some of these include
gasoline, turpentine, lacquer thinner, paint thinner,
chlorinated cleaning solvents, ammonia and house-
hold detergents containing ammonia. Never use
flammable or combustible solvents around tools.
Repairs
For repairs, return the tool to the nearest service
center listed on the back cover of this operator's
manual.
Maintaining Tool
Keep your tool in good repair by adopting a regular
maintenance program. After six months to one year,
depending on use, return the tool to
a MILWAUKEE
service facility for repairs.
If the tool does not start or operate at full power
with fully charged batteries, clean the contacts
on the battery door. If the tool still does not work
properly, return the tool to a
MILWAUKEE
service
facility for repairs.
Cleaning the Laser Windows
Clean the laser windows with a soft, moist cloth to
keep them clean and clear. Remove battery pack
before cleaning.
Contact Temperature Measurement with K-Type
Probe
Only use K-type Temperature Probes with this
meter.
1.Insert the probe. The unit detects a connection of
a K-type probe and displays the contact tempera-
ture (KTC) as the secondary measurement.
2 The display will continue to update
the contact temperature (KTC)
while the temperature probe reach-
es thermal equilibrium with the
object being measured. The display
will shut off after about 20 min.
3.To return to IR mode, remove the K-type probe.
Temperature Alarm
Press the Alarm button to turn on the alarm func-
tion. If the temperature reading is outside the preset
range, the temperature reading and bell icon will
flash and an alarm will sound.
Muting Alarm
Mute the alarm by pressing the
Alarm button. The bell icon will go
off. The temperature reading will
continue to flash as long as it is
outside the preset range.
Setting Preset Range for the
Alarm
1. To set the alarm range, pull and
hold the trigger and then press
the Alarm button. Repeat to toggle
between LO and HI settings.
2. Pull the trigger to increase the
values, press the Alarm button
to decrease the values. Wait 3
seconds for the ranges to save
and exit.
Low Battery
When the Low Battery icon is dis-
played, change the batteries.