background image

   

                   

RF-Optima W R2 PLUS thermostat

     

                                                                     

LVS vloerverwarming BV | Flemingstraat 9 | 1704SL Heerhugowaard | NETHERLANDS | T: +31 (0)72 5400560 | [email protected] 

 

This surface-mounted radio thermostat has been developed to be able to switch electric and conventional heating systems 

on and off using a set temperature and time. It can pair with various receivers for remote control.   

 
 
 
 
 
 
 
 
 
 

Functions   

 

  Large display can be clearly read with the background lighting. 

  Easy to fit thermostat and receiver. 

  Five buttons make it easy to use. 

  4 periods of each day programmable 

  The display shows the set temperature as well as the measured temperature, time. 

  Temperature display in degrees Celsius. 

  The thermostat is supplied with a wall-fixing frame, base

 

 

Technical Data   

 

 

Thermostat operating voltage: 

 

2 x AAA 1.5 V, alkaline batteries. 

Backup storage: 

 

 

 

 

EEPROM 

Receiver operating voltage:   

 

230 VAC, 50/60 Hz 

Frequency: 

 

 

 

 

 

868 MHz 

Switching options:   

 

 

 

7day, 4 periods each day.   

Receiver switch contacts: 

 

 

NO and NC. 

Temperature settings: 

 

 

 

5°C ~ 35°C, 0.5°C increments. 

Accuracy:   

 

 

 

 

 

+/- 0.5°C   

Thermostat dimensions:   

 

 

Surface mounted, 135mm x 87.5 mm x 23.2mm. 

Color:  

 

 

 

 

 

 

White 

IP protection rating:   

 

 

 

20. 

Certification: 

 

 

 

 

 

CE, Rohs, RED 

 

When the thermostat is combined with a Optima PLUS receiver with WiFi the thermostat can be controlled via the 

TUYA or SMARTLIFE app. 

 

 

Summary of Contents for RF-Optima W R2 PLUS

Page 1: ...le The display shows the set temperature as well as the measured temperature time Temperature display in degrees Celsius The thermostat is supplied with a wall fixing frame base Technical Data Thermostat operating voltage 2 x AAA 1 5 V alkaline batteries Backup storage EEPROM Receiver operating voltage 230 VAC 50 60 Hz Frequency 868 MHz Switching options 7day 4 periods each day Receiver switch con...

Page 2: ...ttons Use 1 for Monday 2 for Tuesday 3 for Wednesday 4 for Thursday 5 for Friday 6 for Saturday and 7 for Sunday PRG Schedule Setting Long press PRG button to enter PRG setting The weekday is fixed from Monday to Sunday 1 7 each day have 4 periods 1 4 Each press of PRG button can into next item setting The time and temperature of each period i can be set in following steps 1 Press PRG and hold for...

Page 3: ... Menu Description Range Default Value 01 Temp calibration for internal sensor 8 8 0 02 Set Point Max 5 35 35 03 Set Point Min 5 35 5 04 Sensor Select 0 Internal sensor 1 External sensor 2 Internal External sensor 2 05 Frost Protection Temp 5 15 5 06 Floor Temp Display Read Only 08 High temp protection 20 C 80 C 32 09 Dead zone 0 3 0 10 Display 0 Room temp 1 SET temp 0 11 Child Lock 0 Disable 1 Ena...

Page 4: ...n lock you can long press SET button 5 seconds to unlock Menu 12 This function allows you to save energy When enable Open Window Detection function the system will automatically stop heating when it detects a sudden drop of room temperature 2 C in 15 minutes as default This is normally caused when a window or door is opened without turning off the heating device The device will return to the previ...

Reviews: