Operating Temperature 
   Battery and Charger    ....................32°F to 150°F

(0°C to 65°C)

   Battery and Tool ................................0°F to 167°F

(-18°C to 75°C)  

FUNCTIONAL DESCRIPTION

1

3

4

2

6

8

10

5

7

1.

Heads

2.

Extension 

poles

3.

Extension 

latches

4.

Control 

panel

5.

Upper 

handle

6.

Leg release button

7.

Legs

8.

Carrying 

handle

9.

AC outlet door

10. Battery 

bay/

Charger

11. Battery 

power

indicator

12. Brightness 

indicator

13. AC power indicator
14. Decrease brightness

button

15. Power 

button

16. Increase brightness

button

11

13

14 15 16

9

12

GROUNDING

WARNING

  Improperly con-

necting the grounding wire can result in the 
risk of electric shock. Check with a qualifi ed 
electrician if you are in doubt as to whether the 
outlet is properly grounded. Do not modify the 
plug provided with the tool. Never remove the 
grounding prong from the plug. Do not use the 
tool if the cord or plug is damaged. If damaged, 
have it repaired by a MILWAUKEE service facility 
before use. If the plug will not fi t the outlet, have 
a proper outlet installed by a qualifi ed electrician.

Grounded Tools: 

Tools with Three Prong Plugs

Tools marked “Grounding Required” have a three 
wire cord and three prong grounding plug. The plug 
must be connected to a properly grounded outlet 
(See Figure A). If the tool should electrically mal-
function or break down, grounding provides a low 
resistance path to carry electricity away from the 
user, reducing the risk of electric shock.
The grounding prong in the plug is connected through 
the green wire inside the cord to the grounding sys-
tem in the tool. The green wire in the cord must be 

• Never service damaged battery packs. 

Service of

battery packs should only be performed by the manu-
facturer or authorized service providers.

SPECIFIC SAFETY RULES

• Warning - The lens may get hot during use.

 To reduce

the risk of burns, do not touch hot lens.

• Maintain labels and nameplates.

 These carry impor-

tant information. If unreadable or missing, contact a
MILWAUKEE service facility for a free replacement.

SAVE THESE 

INSTRUCTIONS

SYMBOLOGY

Volts

 Direct 

Current

 Alternating 

Current

 Amps

 Hertz

 Double 

Insulated

C

US

UL Listing for Canada and U.S.

CAUTION

Bright Light - Do Not Stare Into Light

1.

2.

 Always extend legs before raising the 

poles.

Keep hands clear of housing when 
collapsing the extension poles.

Read operator’s manual.

SPECIFICATIONS

Cat. No. ..................................................... 2135-20

AC Input Volts ....................................................120
DC Input Volts......................................................18
DC Output Volts ...................................................18
AC Input Amps....................................................2.1
DC Output Amps.................................................1.8

Battery Cat. No.................................... 48-11-1815

Volts .............................................................. 18  DC

Battery Cat. No.................................... 48-11-1820

Volts .............................................................. 18  DC

Battery Cat. No.................................... 48-11-1828

Volts .............................................................. 18  DC

Battery Cat. No.................................... 48-11-1840

Volts .............................................................. 18  DC

Battery Cat. No.................................... 48-11-1850

Volts .............................................................. 18  DC

Battery Cat. No.................................... 48-11-1860

Volts .............................................................. 18  DC

Battery Cat. No.................................... 48-11-1890

Volts .............................................................. 18  DC

ASSEMBLY

WARNING

 Recharge only with

the charger specifi ed for the battery. For specifi c 
charging instructions, read the operator’s manual 
supplied with your charger and battery. 

Inserting/Removing Battery Pack

Insert 

the battery pack by sliding battery pack into the 

battery bay. Insert the battery pack until the battery 
latches lock. 
To 

remove

 the battery pack, press in both battery 

latches and slide the battery pack out of the battery bay.

Inserting/Removing Extension Cord

When not using the AC option, make sure the AC 
doors are closed completely.
To operate the light on AC power, extend and lock 
legs. Open the 

 door and plug a suitable extension 

cord into the light. To disconnect the extension cord, 
press the Power 

 button to turn off the light, then 

remove the cord from the outlet.

NOTE:

 When an extension cord is plugged into the 

light, the light will automatically run on AC power.

WARNING

 To reduce the risk of

injury, do not look directly into the light when the 
light is on.
To reduce the risk of injury, always fully extend and 
lock legs into position before raising the poles. 
Light may tip and cause injury.
To reduce the risk of injury, keep hands clear of 
the housing area when collapsing the extension 
poles. Head may descend rapidly, pinching hands 
and fi ngers.

Extending/Collapsing the Legs

Always extend and lock legs before raising the poles.
1. Stand light upright.
2. Press the Leg Release Button and slide the legs

down using the Carrying Handle.

3. Lift up on the Upper Handle while sliding down the

Carrying Handle.

4. Lift until the Battery Bay lifts off the fl oor and the

legs lock into place.

5.  To collapse, press the Leg Release Button and slide

in the legs using the Carrying Handle. Keep hands
clear of the legs as they collapse.

Extending/Collapsing the Extension Poles

Extend or collapse the two poles to set the light at the 
desired height.
1. Extend and lock the legs.
2.  Open the top extension latch and raise the head out 

of the housing. Extend the pole to the desired height.

3. Fully close top extension latch.
4. If more height is needed, fully extend fi rst pole and 

close latch before opening bottom latch.

5. Continue to raise the head to the desired height.
6. Fully close bottom extension latch.
7. Rotate the heads to the desired angle. The three

heads can be adjusted individually.

NOTE:

 Before collapsing the poles, the heads must 

be returned to their upright angle.

the only wire connected to the tool's grounding 
system and must never be attached 

Fig. A

to an electrically “live” terminal.
Your tool must be plugged into an 
appropriate outlet, properly installed 
and grounded in accordance with 
all codes and ordinances. The plug 
and outlet should look like those in 
Figure A.

Double Insulated Tools: 

Tools with Two Prong Plugs

Tools marked “Double Insulated” do not require 
grounding. They have a special double 

  Fig. B   Fig. C

insulation system which satisfies 
OSHA requirements and complies with 
the applicable standards of Underwrit-
ers Laboratories, Inc., the Canadian 
Standard Association and the Na-
tional Electrical Code. Double Insulated tools may be 
used in either of the 120 volt outlets shown in
Figures B and C.  

EXTENSION CORDS

Grounded tools require a three wire extension 
cord. Double insulated tools can use either a two 
or three wire extension cord. As the distance from 
the supply outlet increases, you must use a heavier 
gauge extension cord. Using extension cords with 
inadequately sized wire causes a serious drop in 
voltage, resulting in loss of power and possible tool 
damage. Refer to the table shown to determine the 
required minimum wire size.
The smaller the gauge number of the wire, the greater 
the capacity of the cord. For example, a 14 gauge 
cord can carry a higher current than a 16 gauge cord. 
When using more than one extension cord to make 
up the total length, be sure each cord contains at 
least the minimum wire size required. If you are using 
one extension cord for more than one tool, add the 
nameplate amperes and use the sum to determine 
the required minimum wire size.

Guidelines for Using Extension Cords

• If you are using an extension cord outdoors, be sure 

it is marked with the suffi x “W” to indicate that it is 
acceptable for outdoor use.

• Be sure your extension cord is properly wired and in 

good electrical condition. Always replace a damaged 
extension cord or have it repaired by a qualifi ed 
person before using it.

• Protect your extension cords from sharp objects,

excessive heat and damp or wet areas.

Recommended Minimum Wire Gauge

For Extension Cords*

Extension Cord Length

Nameplate

Amperes

25'

50'

75'

100'

150'

0 - 2.0

2.1 - 3.4
3.5 - 5.0
5.1 - 7.0

7.1 - 12.0

12.1 - 16.0
16.1 - 20.0

18
18
18
18
16
14
12

18
18
18
16
14
12
10

18
18
16
14
12
10

--

18
16
14
12
10

--
--

16
14
12
12

--
--
--

* Based on limiting the line voltage drop to fi ve volts at 150% 

of the rated amperes.

READ AND SAVE ALL INSTRUCTIONS 

FOR FUTURE USE.

Reviews: