GENERAL POWER TOOL           

SAFETY WARNINGS

WARNING

Read all safety warnings, instruc-

tions,  illustrations  and  specifica

-

tions provided with this power tool. 

Failure to 

follow all instructions listed below may result in 

electric  shock,  fire  and/or  serious  injury. 

Save all 

warnings and instructions for future reference. 

The term "power tool" in the warnings refers to your 

mains-operated (corded) power tool or battery-oper-

ated (cordless) power tool.

WORK AREA SAFETY

• Keep work area clean and well lit. 

Cluttered or 

dark areas invite accidents.

• Do not operate power tools in explosive atmo-

spheres, such as in the presence of flammable 

liquids, gases or dust. 

Power tools create sparks 

which may ignite the dust or fumes.

• 

Keep children and bystanders away while operat

-

ing a power tool. 

Distractions can cause you to lose 

control.

ELECTRICAL SAFETY

• Power tool plugs must match the outlet. Never 

modify the plug in any way. Do not use any 

adapter plugs with earthed (grounded) power 

tools. 

Unmodified plugs and matching outlets will 

reduce risk of electric shock.

• 

Avoid body contact with earthed or grounded 

surfaces, such as pipes, radiators, ranges and 

refrigerators. 

There is an increased risk of electric 

shock if your body is earthed or grounded.

• Do not expose power tools to rain or wet condi-

tions. 

Water entering a power tool will increase the 

risk of electric shock.

• 

Do not abuse the cord. Never use the cord for 

carrying, pulling or unplugging the power tool. 

Keep cord away from heat, oil, sharp edges or 

moving parts. 

Damaged or entangled cords increase 

the risk of electric shock.

• When operating a power tool outdoors, use an 

extension cord suitable for outdoor use. 

Use of 

a cord suitable for outdoor use reduces the risk of 

electric shock.

• If operating a power tool in a damp location is 

unavoidable, use a ground fault circuit interrupter 

(GFCI) protected supply. 

Use of an GFCI reduces 

the risk of electric shock. 

PERSONAL SAFETY

• Stay alert, watch what you are doing and use 

common sense when operating a power tool. Do 

not use a power tool while you are tired or under 

the influence of drugs, alcohol or medication. 

moment of inattention while operating power tools 

may result in serious personal injury.

• 

Use  personal  protective  equipment.  Always 

wear eye protection. 

Protective equipment such 

as a dust mask, non-skid safety shoes, hard hat or 

hearing protection used for appropriate conditions 

will reduce personal injuries. 

• Prevent unintentional starting. Ensure the switch 

is in the off-position before connecting to power 

source and/or battery pack, picking up or carrying 

the tool. 

Carrying power tools with your finger on 

the switch or energizing power tools that have the 

switch on invites accidents.

• 

Remove  any  adjusting  key  or  wrench  before 

turning the power tool on.

 A wrench or a key left 

attached to a rotating part of the power tool may 

result in personal injury.

• Do not overreach. Keep proper footing and 

balance at all times. 

This enables better control 

of the power tool in unexpected situations.  

• Dress properly. Do not wear loose clothing or 

jewelry. Keep your hair and clothing away from 

moving parts. 

Loose clothes, jewelry or long hair 

can be caught in moving parts.

• If devices are provided for the connection of 

dust extraction and collection facilities, ensure 

these are connected and properly used. 

Use of 

dust collection can reduce dust-related hazards.

• 

Do not let familiarity gained from frequent use 

of tools allow you to become complacent and 

ignore tool safety principles. 

A careless action can 

cause severe injury within a fraction of a second.

POWER TOOL USE AND CARE

• Do not force the power tool. Use the correct power 

tool for your application. 

The correct power tool 

will do the job better and safer at the rate for which 

it was designed.

• Do not use the power tool if the switch does not 

turn it on and off. 

Any power tool that cannot be 

controlled with the switch is dangerous and must be 

repaired.

• Disconnect the plug from the power source and/

or remove the battery pack, if detachable, from 

the power tool before making any adjustments, 

changing accessories, or storing power tools. 

Such preventive safety measures reduce the risk of 

starting the power tool accidentally.

• Store idle power tools out of the reach of children 

and do not allow persons unfamiliar with the 

power tool or these instructions to operate the 

power tool. 

Power tools are dangerous in the hands 

of untrained users.  

• Maintain power tools and accessories. Check 

for  misalignment  or  binding  of  moving  parts, 

breakage of parts and any other condition that 

may affect the power tool’s operation. If damaged, 

have the power tool repaired before use. 

Many ac-

cidents are caused by poorly maintained power tools.

• Keep cutting tools sharp and clean. 

Properly 

maintained cutting tools with sharp cutting edges 

are less likely to bind and are easier to control.

• 

Use the power tool, accessories and tool bits 

etc. in accordance with these instructions, 

taking into account the working conditions and 

the work to be performed. 

Use of the power tool 

for operations different from those intended could 

result in a hazardous situation.

• Keep handles and grasping surfaces dry, clean 

and free from oil and grease. 

Slippery handles and 

grasping surfaces do not allow for safe handling and 

control of the tool in unexpected situations.

BATTERY TOOL USE AND CARE

• Recharge only with the charger specified by the 

manufacturer. 

A charger that is suitable for one type 

of battery pack may create a risk of fire when used 

with another battery pack.

• 

Use power tools only with specifically designated 

battery packs. 

Use of any other battery packs may 

create a risk of injury and fire.

• 

When battery pack is not in use, keep it away 

from other metal objects, like paper clips, coins, 

keys, nails, screws or other small metal objects, 

that can make a connection from one terminal 

to another. 

Shorting the battery terminals together 

may cause burns or a fire. 

• 

Under abusive conditions, liquid may be ejected 

from the battery; avoid contact. If contact ac

-

cidentally  occurs,  flush  with  water.  If  liquid 

contacts eyes, additionally seek medical help. 

Liquid ejected from the battery may cause irritation 

or burns.

• 

Do not use a battery pack or tool that is dam

-

aged or modified. 

Damaged or modified batteries 

may exhibit unpredictable behavior resulting in fire, 

explosion or risk of injury.

• 

Do not expose a battery pack or tool to fire or 

excessive temperature. 

Exposure to fire or tem

-

perature above 265°F (130°C) may cause explosion.

• Follow all charging instructions and do not charge 

the battery pack or tool outside the temperature 

range  specified  in  the  instructions. 

Charging 

improperly or at temperatures outside the specified 

range may damage the battery and increase the risk 

of fire.

SERVICE

• Have  your  power  tool  serviced  by  a  qualified 

repair person using only identical replacement 

parts. 

This will ensure that the safety of the power 

tool is maintained.

• Never service damaged battery packs. 

Service 

of battery packs should only be performed by the 

manufacturer or authorized service providers.

SPECIFIC SAFETY RULES FOR 

PRESS TOOL

• Use tool only as directed. Only trained personnel 

should operate tool. 

• Do not use tool without press jaw installed. 

Fingers could be crushed.

• Keep hands away from press jaw while tool is 

in use. 

Fingers could be crushed.

 To reduce the risk of injury, wear safety goggles 

or glasses with side shields. Inspect and discard 

workpieces  with  cracks  or  wear  before  use. 

Materials may crack or shatter. 

• Use tool only with MILWAUKEE or MILWAUKEE 

approved press jaws, press fittings, and pipe for 

which they are designed. 

Other uses may cause 

injury or damage to the tool, accessories, and pipes. 

Leaking may result.

• Only use press jaw with a compression range 

rated for this tool.

 

Maintain  labels  and  nameplates. 

These carry 

important  information.  If  unreadable  or  missing, 

contact a MILWAUKEE service facility for a free 

replacement.

• 

WARNING

Some dust created by power sanding, 

sawing, grinding, drilling, and other 

construction activities contains chemicals known to 

cause cancer, birth defects or other reproductive 

harm. Some examples of these chemicals are:

• lead from lead-based paint

• crystalline silica from bricks and cement and other 

masonry products, and

• arsenic and chromium from chemically-treated 

lumber.

  Your risk from these exposures varies, depending on 

how often you do this type of work. To reduce your 

exposure to these chemicals: work in a well ventilated 

area, and work with approved safety equipment, such 

as those dust masks that are specially designed to 

filter out microscopic particles.

SYMBOLOGY

 

  

Volts

 

 

Direct Current

 

  MET Laboratories

 

 

United States and Canada   

 

 

Always wear eye protection

SPECIFICATIONS

Cat. No. ................................................... 2773-20L 

Volts

..............................................................

18 DC

Watts

 .................................................................

450

Nominal Force

 ...........................................

7200 lbs

Compression Range

   Copper and Stainless

 ............

  < Ø 4"  (100 mm)

   Iron Pipe and Stainless

..........

  < Ø 2"   (50 mm)

   Black Iron Pipe

 ......................

  < Ø 2"   (50 mm)

Battery Type

 .................................................

M18™

Charger Type

................................................

M18™

Recommended Ambient 

   Operating Temperature

 ......................

0°F to 125°F

FUNCTIONAL DESCRIPTION

8

1. Red LED

2. Green LED

3. Start button

4. Release button

5. Handle 

6. Indexing pin

7. Retaining pin

8. Finger guard

3

5

4

7

6

1

2

Summary of Contents for M18 FORCELOGIC 2773-20L

Page 1: ...8 FORCELOGIC OPERATOR S MANUAL MANUEL de L UTILISATEUR MANUAL del OPERADOR WARNING To reduce the risk of injury user must read and understand operator s manual AVERTISSEMENT Afin de r duire le risque...

Page 2: ...Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the power tool s operation If damaged have the power tool repaired before use Many ac ciden...

Page 3: ...e them Cleaning Clean dust and debris from vents Keep handles clean dry and free of oil or grease Use only mild soap and a damp cloth to clean since certain clean ing agents and solvents are harmful t...

Page 4: ...duit les risques de choc lectrique Si l utilisation d un outil lectrique est in vitable dans un endroit humide utiliser une source d alimentation munie d un disjoncteur de fuite de terre L utilisation...

Page 5: ...te d arr t 180 1 puis tirez 2 2 Ins rez la t te de sertissage 3 Poussezlaclavetted arr t 1 puistournez 180 2 1 2 1 2 ATTENTION Pour viter d endommager l outil n utilisez pas l outil sans la cla vette...

Page 6: ...CETTE CONDITION VOUS NE DEVEZ PAS ACHETER LE PRODUIT EN AUCUN CAS MILWAUKEE NE SAURAIT TRE RESPONSABLE DE TOUT DOMMAGE ACCESSOIRE SP CIAL OU INDIRECT DE DOMMAGES INT R TS PUNITIFS OU DE TOUTE D PENSE...

Page 7: ...monedas llaves clavos tornillos u otros objetos met licos peque os que puedan formar una conexi n de una terminal a otra Crear un corto entre las terminales de la bater a puede ocasionar quemaduras o...

Page 8: ...haya espacio entre los segmentos del collar de la prensa o las puntas de las mordazas al finalizar el prensado Limitaci n de la carrera Al utilizar cabezas de prensado distintas a las de la Mordaza ad...

Page 9: ...DO PRODUCTO DE MILWAUKEE SI USTED NO ACEPTA ESTA CONDICI N NO DEBE COMPRAR EL PRODUCTO MILWAUKEE NO SER RE SPONSABLE EN NING N CASO DE DA OS INCIDENTALES ES PECIALES EMERGENTES O PUNITIVOS NI DE NING...