5
CAUTION
To prevent damage to the cable, do not
use in larger diameter pipes.
Cable Installation
WARNING
To reduce the risk of injury, wear
safety goggles or glasses with side
shields. Always wear leather gloves. The cable is
under pressure and can uncoil unexpectedly. Cable
tip may be sharp.
Remove the cable for cleaning after each use. Differ-
ent size and types of cables are available for different
applications.
To remove the cable:
1. Remove the battery pack and set the front handle to
the feed position
according to the instructions in
"Controlling the Cable".
2. Pull the cable out through the front handle until the
end of cable indicator is reached
.
NOTE:
Cable will appear stuck once the end of cable
indicator is reached.
3. Set the front handle to the neutral position and pull
out the remaining cable.
To install the cable:
1. Remove the battery pack and set the front handle to
the locked position
according to the instructions
in "Controlling the Cable".
2. Insert the cable through the nose of the tool until the
cable catches.
3. Set the front handle to the feed position
and
continue feeding the cable through the front handle.
4. Remove the protective tip cover from new cables
before use.
Cable Attachment Installation
To install the attachment:
Snap the attachment coupler into the cable coupler.
Test the cable before inserting into the drain to make
sure the attachment does not fall off during use.
To remove the attachment:
Insert the pin key into the coupling hole and pull attach-
ment off of cable.
ASSEMBLY
WARNING
Recharge only with the charger
-
manual supplied with your charger and battery.
Removing/Inserting the Battery
To
remove
the battery, push in the release buttons and
pull the battery pack away from the tool.
WARNING
Always remove battery pack before
changing or removing accessories.
To
insert
the battery, slide the pack into the body of the
tool. Make sure it latches securely into place.
WARNING
recommended for this tool. Others
may be hazardous.
Always store tool in its bucket to avoid damage
to the cable.
SPECIFICATIONS
Cat. No. ..................................................M18 FDCPF8
Volts ...................................................................18 DC
Cable Spin No Load RPM ................................0 - 600
Cable Feed Speed Inches/Second .....0-203mm (0-8")
Battery Type ..................................................... M18™
Charger Type .................................................... M18™
Recommended Ambient
Operating Temperature ....................-17°C to 51°C
SYMBOLOGY
V
V
olts
Direct
Current
No-Load Revolutions per Minute (RPM)
FUNCTIONAL DESCRIPTION
6
8
5
7
1
3
4
9
11
1. Cable
2. Front handle/Twist lock
3. Rubber drum shield
4. Drum cover
5. Forward/reverse switch
6. Handle
7. Trigger switch
8. Flat tool base
9. LED
10. Cable feed icon
11. Cable lock icon
2
10
Only wear leather gloves
Do not allow battery to contact
corrosive or conductive fluid.
n
o
xxxxmin.
-1
Summary of Contents for M18 FDCPF8
Page 2: ...2...