background image

5

Maintaining Tool 

Keep your tool, battery pack and charger in good repair 

by adopting a regular maintenance program. 

After six months to one year, depending on use, return 

the tool, battery pack and charger to the store where 

the product was originally purchased or one of our 

authorised MILWAUKEE® FORCELOGIC™ service 

centres for:

• Lubrication

•  Mechanical inspection and cleaning (gears, spindles, 

bearings, housing, etc.)

• Electrical inspection (battery pack, charger, motor)

• Testing to assure proper mechanical and electrical 

operation

If the tool does not start or operate at full power with a 

fully charged battery pack, clean the contacts on the 

battery pack. If the tool still does not work properly, 

return the tool, charger and battery pack, to the store 

where the product was originally purchased or one 

of our authorised MILWAUKEE® FORCELOGIC™ 

service centres.

MAINTENANCE

WARNING 

To reduce the risk of injury, 

always unplug the charger and remove the 

battery pack from the charger or tool before 

performing  any  maintenance.  Never  disas-

semble  the  tool,  battery  pack  or  charger. 

Contact a MILWAUKEE® service facility for 

ALL repairs.

ACCESSORIES

CUSTOMER SERVICE

For a complete listing of accessories refer to your 

MILWAUKEE® accessories catalogue or go online to 

milwaukeetools.com.au or milwaukeetools.co.nz.  To 

obtain a catalogue, contact the store where the product 

was originally purchased or one of our authorised 

MILWAUKEE®  FORCELOGIC™ service centres.

WARNING 

Always remove battery pack 

before  changing  or  removing  accessories. 

Only use accessories specifically recommend-

ed  for  this  tool.  Others  may  be  hazardous. 

Cleaning

Clean dust and debris from charger and tool vents. 

Keep tool handles clean, dry and free of oil or grease. 

Use only mild soap and a damp cloth to clean the 

tool, battery pack and charger since certain cleaning 

agents and solvents are harmful to plastics and other 

insulated parts. Some of these include gasoline, 

turpentine, lacquer thinner, paint thinner, chlorinated 

cleaning solvents, ammonia and household detergents 

containing ammonia. Never use flammable or 

combustible solvents around tools.

Repairs

For repairs, return the tool, jaws, rings, battery 

pack and charger to the store where the product 

was originally purchased or one of our authorised 

MILWAUKEE® FORCELOGIC™ service centres.

WARNING 

To reduce the risk of per 

sonal injury and damage, never immerse your 

tool, battery pack or charger in liquid or allow 

a liquid to flow inside them.

Troubleshooting

LED

Cause

Solution

Green LED 

flashing

The battery is not sufficiently charged 

to complete a pressing operation.

Charge the battery. 

The retaining pin is not correctly shut 

or has come loose.

Insert the retaining pin, or check the 

retaining pin and cylinder. 

NOTE: the pressing operation may 

not have been completed. Check and 

repeat if necessary.

Red LED 

flashing

Device not within operating 

temperature range.

Bring device into operating 

temperature range (-10°C to 50°C)

Red LED on

Device fault

Retry operation. If Red LED remains 

lit, return the tool, charger and battery 

pack, to a 

MILWAUKEE®

 service 

facility for repairs.

Green and Red 

LED flashing 

alternately

Service needed

Return the tool, charger and battery 

pack, to a 

MILWAUKEE®

 service 

facility for maintenance.

Australia:

 1300 MILWAUKEE (1300 645 928)

www.milwaukeetools.com.au

 

New Zealand:

 0800 279 624

www.milwaukeetools.co.nz

Summary of Contents for FORCELOGIC M18BLHPT-501B

Page 1: ...M18 BRUSHLESS FORCELOGIC PRESS TOOL OPERATOR S MANUAL TO REDUCE THE RISK OF INJURY USER MUST READ AND UNDERSTAND OPERATOR S MANUAL Cat No M18BLHPT 0...

Page 2: ...power tool in the warnings refers to your mains operated corded power tool or battery operated cordless power tool POWER TOOL USE AND CARE Do not force the power tool Use the correct power tool for yo...

Page 3: ...ced by a qualified repair person using only identical replacement parts This will ensure that the safety of the power tool is maintained 1 Start button 2 Green LED Recommended to use tool only with MI...

Page 4: ...al use e g plumbing mechanical press freely and pay attention to the LED indicators see Troubleshooting 8 If the red LED lights press the start button If the tool does not run return the tool to the s...

Page 5: ...this tool Others may be hazardous Cleaning Clean dust and debris from charger and tool vents Keep tool handles clean dry and free of oil or grease Use only mild soap and a damp cloth to clean the tool...

Page 6: ...other terms material or workmanship a defect in its express or implied by statute custom or common law are excluded Nothing contained in these terms and conditions excludes or restricts any consumer...

Page 7: ...er VIC 3108 Fax 1800 807 993 Contact during normal business hours email milwaukee ttibrands com au TECHTRONIC INDUSTRIES N Z LIMITED 18 26 Amelia Earhart Avenue Mangere Auckland 2022 N Z Tel 09 573 02...

Page 8: ...Electric Tool Corporation Australia Techtronic Industries Australia Pty Ltd Doncaster Victoria Australia 3108 Milwaukee Electric Tool Corporation New Zealand Techtronic Industries New Zealand Pty Ltd...

Reviews: