background image

4

5

TERMINOLOGY

Magazine 

Capacity

106 nails

Operating 

Pressure

min. 70 PSI

max. 120 PSI

Cat. 

No.

7150-21

Speci

fi

 cations

Symbology

Air 

Consumption

.04 ft

3

/cycle at 

100 psi

Air 

Inlet

1/4

 

 in. 

NPT

Read the Operator's Manual

Wear Eye Protection

Keep hands away

Fastener 

Length

min. 0.625"

max. 2.125"

Collation 

Angle

Fastener 

Size

18 gauge

Actuate

To cause movement of the tool component(s) 
intended to drive a fastener.

Actuation System

The  use  of  a  trigger,  workpiece  contact 
and/or  other  operating  control,  separately 
or  in  some  combination  or  sequence,  to 
actuate the tool.

  •  Single sequential actuation

 

An  actuation  system  that  requires  the 
workpiece contact and then the trigger 
to be activated in a speci

fi

 c sequence 

to drive a fastener.  Additional actuation 
can occur when the trigger is released 
and reactivated.

  •  Contact actuation

 

An  actuation  system  that  requires  the 
workpiece contact and the trigger to be 
activated  in  any  sequence  to  drive  a 
fastener.  Additional actuation can occur 
when either the workpiece contact or the 
trigger is released and reactivated.

  •  Selective actuation

 

An actuation system that allows selec-
tion  of  actuation  systems:  single  se-
quential actuation or contact actuation. 

Fastener

A staple, pin, brad, nail, or other fastening 
device which is designed and manufactured 
for use in the tools.

Jam

An obstruction in the feed or drive areas of 
the tool.

Workpiece Contact

An  operating  control  element  on  the  tool 
intended  to  be  activated  by  the  workpiece 
to be fastened.

SPECIFIC SAFETY INSTRUCTIONS

9. 

Do not operate a tool if any portion of 
the tool operating controls is inoper-
able, 

disconnected, altered, or not work-

ing properly. This will cause unexpected 
actuation, resulting in serious injury.

10. 

Always keep hands and body away 
from discharge area of the tool

. Never 

attempt  to  clear  a  jammed  workpiece 
contact by grasping the discharge area 
of the tool.  Fasteners discharged from 
tool  can  cause  serious  injury  if  they 
contact hands or body. 

11. 

Do  not  drive  fasteners  close  to  the 
edge of the workpiece

. Fasteners can 

slip off corners and edges or penetrate 
through  thin  material,  making  them 
projectiles  capable  of  causing  serious 
injury.

12. 

Use  the  tool  only  for  the  intended 
purpose. Do not abuse the tool

. Do 

not use as a hammer, stamp or engrave 
information onto parts, drop or impact 
the tool or otherwise apply excess force 
to  the  tool  in  use.  Do  not  mount  the 
tool to stands or modify it for stationary 
use.

13. 

Do not carry tool by the air hose. 

Only 

carry  the  tool  by  the  handle  with  your 

fi

 nger off of the trigger.

14. 

Do  not  use  this  tool  without  the 
safety  warning  label  in  place

.  If  the 

label  is  damaged  or  missing,  contact 

MILWAUKEE

 for a free replacement.

1. 

Use air supply hoses with a minimum 
working pressure rating of 200 psi.

2.

  Use pressure regulators to limit the 

air pressure supplied to the tool. Set 
the  regulators  to  no  more  than  120 
psi.

3. 

Install only hose couplings that will 
allow all pressure to be removed from 
tool  when  disconnected  from  the 
source

. If the wrong 

fi

 tting is installed, 

pressure  may  remain  in  the  tool  after 
disconnection,  allowing  it  to  drive  a 
fastener, possibly causing injury.

4. 

Prior to each use, check workpiece 
contact  and  trigger  for  correct  op-
eration

. Do not disassemble or clamp 

parts of the workpiece contact, trigger, 
or  driving  mechanism. This  will  cause 
unexpected actuation, resulting in seri-
ous injury.

5. 

Never point the discharge area of the 
tool at any body parts or at other peo-
ple

. Always assume the tool is loaded 

and capable of driving a fastener.

6. 

Do  not  actuate  the  tool  into  free 
space

.  Do  not  engage  in  horseplay. 

The discharged fasteners are projectiles 
capable of causing serious injury.

7. 

When  using  the  tool,  ensure  the 
workpiece contact is securely placed 
on the workpiece

. Hold the tool 

fi

 rmly 

and be prepared for the recoil.

8. 

Do  not  remove,  tamper  with,  or 
otherwise  cause  the  tool  operating 
controls to become inoperable. 

This 

will cause unexpected actuation, result-
ing in serious injury.

tool  or  serious  injury  to  persons.  Use 
only clean, dry, regulated compressed 
air  at  the  rated  pressure  or  within  the 
rated pressure range as marked on the 
tool. Prior to using the tool, always verify 
that the air source has been adjusted to 
the rated air pressure or within the rated 
air-pressure  range. Air  compressors 
should comply with ANSI B19.3.

28. 

DANGER: Do not use oxygen, com-
bustible gases or bottled gases

 as a 

power source for this tool. The tool will 
explode  and  cause  death  or  serious 
injury.

29. 

Never connect to an air source that 
is capable of exceeding 200 psi. 

Over 

pressurizing the tool may result in burst-
ing, abnormal operation, breakage of the 

AIR SOURCE

Summary of Contents for 7150-21

Page 1: ...21 OPERATOR S MANUAL MANUEL de L UTILISATEUR MANUAL del OPERADOR TO REDUCE THE RISK OF INJURY USER MUST READ OPERATOR S MANUAL AFIN DE R DUIRE LES RISQUES DE BLESSURES L UTILISATEUR DOIT LIRE LE MANUE...

Page 2: ...se is able to cause hearing loss 14 Do not carry an air hose or a tool con nected to an air hose when climbing ladders rigging or scaffolding Do not attach an air hose or tool con nected to an air hos...

Page 3: ...e tool Do not use as a hammer stamp or engrave information onto parts drop or impact the tool or otherwise apply excess force to the tool in use Do not mount the tool to stands or modify it for statio...

Page 4: ...hook Front of tool End cap Screw 2 Air inlet Removing and Installing the Belt Hook To remove the hook 1 Rotate the hook until it snaps into one of the preset positions 2 Remove the two mounting screw...

Page 5: ...rtion 3 Snap the air hose onto the quick con nector 4 Check for air leakage Fig 2 Pusher release button 3 Verify that the magazine is empty and then connect the air supply to the tool Point of nails i...

Page 6: ...aused by a fastener or part of a fastener wedging between the driver blade and the nail guide Fastener strips with an incorrect collation angle or the wrong fas tener type may cause continuous jamming...

Page 7: ...rate Continue to pull and hold the trigger and push the workpiece contact against a workpiece The tool must not operate Without pulling the trigger press the workpiece contact against a workpiece Pull...

Page 8: ...KEE tool is tested before leaving the factory and is warranted to be free from defects in material and workmanship MILWAUKEE will repair or replace at MILWAUKEE s discretion without charge any tool in...

Reviews: