background image

9

Instruction Manual

SECTION 4 - OPERATING SPECIFICATIONS

Supply Pressure

Regulated 40-100 psi.

CDA (Instrument) Pressure Range

3-15 psi standard, other pressure ranges available on

 

special order.

Pump Capacity Variation over Instrument 

Pressure Range

0-100% rated capacity.

Minimum Pressure Change Required to Reset 

Capacity

0.20 psi or 0.13% of full range pressure.

Linearity of Actuator Movement

Within 5% of maximum capacity (maximum difference 

in output between calibration curve and most favorable 

straight line drawn through curve).

Repeatable Accuracy of Actuator Position

Within 1% of full stroke. (Maximum difference between 

two positions of output for the same value of input 

always approached from one direction)

Supply Air Consumption (Balanced Condition)

0.2 - 0.4 SCFM

Instrument Air Consumption

0 SCFM

Failure to Supply Pressure (Ps)

Moves to 100% position.

Failure of Instrument Air (PI)

Moves to 0% position.

Summary of Contents for mROY

Page 1: ...mROY Pneumatic Capacity Control Instruction Manual Manual No 53871 Rev 01 Rev Date 05 2019...

Page 2: ......

Page 3: ...umping downhill or into low or no system pressure a back pressure anti siphon device should be installed to prevent over pumping or siphoning Contact your distributor or sales representative for furth...

Page 4: ...AND ASSEMBLY PROCEDURE 7 2 1 DISASSEMBLY 7 2 2 ASSEMBLY 7 2 3 CALIBRATION AFTER ASSEMBLY 7 SECTION 3 GENERAL PERFORMANCE 8 SECTION 4 OPERATING SPECIFICATION 9 SECTION 5 TABLE OF EQUIVALENTS 11 LIST O...

Page 5: ...lation the instrument air pressure Pi and the supply air pressure Ps are connected to the corresponding fittings in the air control valve The supply air Ps is routed internally to the pilot valve and...

Page 6: ...es the range spring feeds back a force proportional to the piston location so that when the range spring pressure plus the diaphragm force from the instrument air signal are again in balance with the...

Page 7: ...p capacity control spool This completes the disassembly 2 2 ASSEMBLY For assembly follow the disassembly procedure in reverse order descending step numbers from 9 to 1 making certain that the O rings...

Page 8: ...ection to increase the capacity setting and up to 110 pounds force in the opposite direction Then with 100 psi air pressure applied these forces are increased to 100 pounds and 275 pounds respectively...

Page 9: ...ressure Linearity of Actuator Movement Within 5 of maximum capacity maximum difference in output between calibration curve and most favorable straight line drawn through curve Repeatable Accuracy of A...

Page 10: ...0 O RING 921 X 139 BUNA N 1000 INT TOOTH LOCK WASHER 6 Z PL 1010 RD HD SCR 6 32NCX7 16 Z PLT 1020 5 16 18 SLOTTED SHOULDER SCREW 1030 O RING 2 011 70 DURO URETHANE 1040 PISTON 1050 O RING 2 226 BUNA N...

Page 11: ...1 gallon hour U S Equals 0 003785 cubic meters hour 0 002228 cubic feet minute 1 horsepower Equals 745 7 Watts 1 inch Equals 2 540 centimeters 1 inch of mercury Equals 0 03442 kilograms square centim...

Page 12: ...e sustainable and efficient environments Our people and our family of brands including Club Car Ingersoll Rand Thermo King and Trane work together to enhance the quality and comfort of air in homes an...