PRECAUTIONS

For Pumps with PVC & 316SS Liquid Ends

WHEN USED IN SWIMMING POOLS OR SPAS/HOT TUBS (ANSI/NSF 50)

Caution on Chemical Concentration:

There is a potential for elevated chemical concentration during periods of no flow, for 
example, during backwash in the system. Steps, such as turning the pump off, should be 
taken during operation or installation to prevent this. Contact your sales representative or 
distributor about other external control options to help mitigate this risk.

Flow Indicating Device:

To ensure operation of the pump it is recommended that some type of flow indicating device 
be installed to measure water flow rates and be appropriate for the output of the pump. 
Contact your distributor or sales representative for further information.

Head Loss / Over Pressure Protection / Back Pressure-Anti-Siphon Valve:

• Milton Roy metering pumps are positive displacement. Head loss is not applicable to the

pump.

• To ensure safe operation of the pump it is recommended that some type of safety/pressure

relief valve be installed to protect the piping and other system components from failing due
to excessive pressure.

• If you are pumping downhill or into low or no system pressure, a back pressure/anti-siphon

device should be installed to prevent over pumping or siphoning. Contact your distributor or
sales representative for further information.

Additional Operation and Installation Instructions for 316SS or PVC Liquid Ends:

• Application of this pump to swimming pool/spas only evaluated to NSF/ANSI 50.
• There is a potential for elevated chemical concentration during periods of no flow, for

example, during backwash in the system. Steps, such as turning the pump off, should be
taken during operation or installation to prevent this. See your sales representative or
distributor about other external control options to help mitigate this risk.

• Liquid Compatibility CAUTION: Determine if the materials of construction included in the

liquid handling portion of your pump are adequate for the solution (chemical) to be pumped.

ALWAYS wear protective clothing, face shield, safety glasses and gloves when working on

or near your metering pump. Additional precautions should be taken depending on the
solution being pumped. Refer to MSDS precautions from your solution supplier. Reference a
Milton Roy Material Selection Chart for aid in selecting appropriate material of construction
for fluids of your specific metering pump. Contact your sales representative or distributor for
further information.

Summary of Contents for mROY

Page 1: ...mROY Pneumatic Capacity Control Instruction Manual Manual No 53871 Rev 01 Rev Date 05 2019...

Page 2: ......

Page 3: ...umping downhill or into low or no system pressure a back pressure anti siphon device should be installed to prevent over pumping or siphoning Contact your distributor or sales representative for furth...

Page 4: ...AND ASSEMBLY PROCEDURE 7 2 1 DISASSEMBLY 7 2 2 ASSEMBLY 7 2 3 CALIBRATION AFTER ASSEMBLY 7 SECTION 3 GENERAL PERFORMANCE 8 SECTION 4 OPERATING SPECIFICATION 9 SECTION 5 TABLE OF EQUIVALENTS 11 LIST O...

Page 5: ...lation the instrument air pressure Pi and the supply air pressure Ps are connected to the corresponding fittings in the air control valve The supply air Ps is routed internally to the pilot valve and...

Page 6: ...es the range spring feeds back a force proportional to the piston location so that when the range spring pressure plus the diaphragm force from the instrument air signal are again in balance with the...

Page 7: ...p capacity control spool This completes the disassembly 2 2 ASSEMBLY For assembly follow the disassembly procedure in reverse order descending step numbers from 9 to 1 making certain that the O rings...

Page 8: ...ection to increase the capacity setting and up to 110 pounds force in the opposite direction Then with 100 psi air pressure applied these forces are increased to 100 pounds and 275 pounds respectively...

Page 9: ...ressure Linearity of Actuator Movement Within 5 of maximum capacity maximum difference in output between calibration curve and most favorable straight line drawn through curve Repeatable Accuracy of A...

Page 10: ...0 O RING 921 X 139 BUNA N 1000 INT TOOTH LOCK WASHER 6 Z PL 1010 RD HD SCR 6 32NCX7 16 Z PLT 1020 5 16 18 SLOTTED SHOULDER SCREW 1030 O RING 2 011 70 DURO URETHANE 1040 PISTON 1050 O RING 2 226 BUNA N...

Page 11: ...1 gallon hour U S Equals 0 003785 cubic meters hour 0 002228 cubic feet minute 1 horsepower Equals 745 7 Watts 1 inch Equals 2 540 centimeters 1 inch of mercury Equals 0 03442 kilograms square centim...

Page 12: ...e sustainable and efficient environments Our people and our family of brands including Club Car Ingersoll Rand Thermo King and Trane work together to enhance the quality and comfort of air in homes an...

Reviews: