General installation and maintenance instructions 

HOSPITAIR PACK S (MV) - 11 bar 

 

Page 3/17 

12/2016 

Manual N° 520003 version 5 

 

 

SECTION 1.  INTRODUCTION 

We strongly advise you to read these installation instructions, before first switching on your air unit. The 
damage that could be caused by setting the machine up or installing it incorrectly would not be covered 
by our guarantee. 

 
In order to simplify any future requests for spare parts or further information about your air unit, we advise you to copy 
onto this page the specifications written on the plates fixed to the air unit and the air treatment unit, as soon as you 
receive your machine. 

1.1. General 

points 

The HOSPITAIR PACK S produces a medical air quality to feed one oxygen generator. 
One HOSPITAIR PACK S unit is required for each oxygen generator. 

1.2. Specification 

plates 

 

 

Type

 

Hospitair

 

units

 

 

Serial

 

number

 

 

Air

 

dryer

 

type

 

 

Serial

 

number

 

 

 

 

 

 

 

SECTION 2.  CHOICE OF ROOM 

The unit must be located in a clean, non-humid, non-saline, dustless and ventilated local whose the temperature should 
be b5C and +40C. 
Forced ventilation controlled by a thermostat must be installed to ensure adequate room ventilation. 
The following formula can be used to size the fan: 

 

The following formula can be used to size the fan: 
 
Q = P x 1000 x 3600  = 2880 x   N   
          

T x 1250                        

 
Q = Ventilation volume (m³/h) 
 
P = Compressor energy consumption (kW) 
 

T = Temperature difference between the local and outdoor 

 
1250 = Volumetric heat capacity Cp (J.m³.K

-1

 
Exemple: Compressor power 16.5 kW 
                

T eligible = 10°C 

                Q = 2880 x 16.5 = 4752 m³/h 
                                    10 
The air inlet area must be dimensioned such that the flow rate does not exceed 3 m/s 
Extreme tolerance of 5 m/s 
 
                S =          Q       =       4752     = 0.44 m

                                     

Vair x 3600    3 x 3600 

 
For information purposes, the table below gives the amounts of heat that must be extracted, according to the installed 
capacity in kW. 

Summary of Contents for HOSPITAIR PACK S MVA 8

Page 1: ...RULES see manual n 511927 Spare parts list and maintenance instructions for compressors First apposition of the EC marking 2009 This document must not be disclosed or reproduced without permission fr...

Page 2: ...ESCRIPTION OF THE OPERATION 5 INSTALLATIONS 7 3 5 DIMENSIONS 7 SECTION 4 ELECTRIC POWER SUPPLY 8 4 1 COMPRESSOR POWER SUPPLY 8 4 2 CONNECTION BETWEEN COMPRESSOR AND PROCOM 2 OF PRO2XY 8 4 3 SUMMARY OF...

Page 3: ...in a safe place and to dispose of it with due care for the environment Dustbin on wheels barred of a cross symbol This symbol indicates that the equipment should not be thrown with domestic waste and...

Page 4: ...2 Specification plates Type Hospitair units Serial number Air dryer type Serial number SECTION 2 CHOICE OF ROOM The unit must be located in a clean non humid non saline dustless and ventilated local w...

Page 5: ...38 37 31 820 1 00 13 500 700 x 700 The person in charge of the installation has overall responsibility of the product environment requirements He is also in charge of setting up methods of struggle ag...

Page 6: ...he pressure before the air treatment unit Then the air enters the filtration chain see the description in the manual concerning the filtration chain At the filtration chain output the air is then stor...

Page 7: ...order given by the oxygen generator 3 4 4 Emergency stop compressor Use the emergency button only in extreme necessity because it stops suddenly the compressor and if the compressor is on charge oil c...

Page 8: ...s HOSPITAIR PACK S MVA 8 MVB 12 MVB 16 HOSPITAIR PACK S MVC 19 MVC 23 HOSPITAIR PACK S MVD 31 MVE 38 MVE 46 3 5 2 Vertical air receivers 500 1000 litres E B A C F 1 2 Soupape Outlet Inlet Pressure gau...

Page 9: ...mpliance with the legislation and regulations in force in your country The wire sections are given for information to 5A mm2 Even so the sections shall be defined by taking contacts with the wire prov...

Page 10: ...report The connection between Alarm report on automate units must be done by the person in charge of the Installation He must control the compliance wiring and proper operation during the final accept...

Page 11: ...rainage system OWAMAT separator used to separate oil and water In compliance with Law No 76 663 dated 19 July 1976 relating to installations classified for protecting the environment Law 92 3 dated 3...

Page 12: ...pen the network outlet valve gradually SECTION 7 CLEANING AND MAINTENANCE IMPORTANT For this operation use all necessary protective measures gloves mask overalls etc then destroy contaminated consumab...

Page 13: ...to stop Check the compressor discharge time before it stops completely 10 to 15 seconds 7 3 Safety relief valve When a relief valve with discharge line operates and must be tested no persons may stand...

Page 14: ...to avoid all forced and tensions and to damp out all vibrations even non visible The base of the receiver will have to support the weight of the receiver including in situation of tests In performing...

Page 15: ...g the compressed air unit object of this technical manual are protected by relief valves as indicated in the table hereafter Component Pressure setting bar Location of the safety relief valve Compress...

Page 16: ...should assure that it is used in such an electromagnetic environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2...

Page 17: ...ufacturer and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey 1 should be less than the compliance level...

Page 18: ...o the maximum output power of the communications equipment Separation distance according to frequency of transmitter Rated maximum output power of transmitter W m 150 kHz to 80 MHz d 1 16 P 80 MHz to...

Page 19: ......

Page 20: ......

Reviews: