EN
Staff: Adjuster Mechanic
Personal protective equipment
•
Protective gloves
•
Protective glasses
•
Protective clothing
•
Wear specific protective clothing if necessary
Equipment for the operation
•
Collecting tank
• PTFE
tape
Figure 13: Position of the drain fitting
✓
The vacuum pump is out of order.
•
Place the collecting tank under the drain fitting.
•
Carefully unscrew the screw of the drain connection.
•
Allow the operating liquid to flow out.
•
Clean the screw and pump threads of the drain connection.
•
Surround the screw with PTFE tape.
•
Screw in the drain connection and tighten to the torque specified in the following table.
The vacuum pump is ready for filling with operating fluid.
Models
S27
S52
S127
S162
S252
S327
Thread size
G 1/4"
G 1/4"
G 1/4"
G 1/2"
G 1/2"
G 1/2"
Tightening torque
20 Nm
20 Nm
20 Nm
50 Nm
50 Nm
50 Nm
Descaling
Aggressive cleaning and rinsing agents.
Pump/pump unit damage.
➢
Determine the type and duration of cleaning according to the sealing and housing
materials used.
Staff: Adjuster Mechanic
Personal protective equipment
• Protective gloves
•
Protective glasses
• Protective clothing
Consumable
•
Descaling agent compatible with the material, the conveyed product and the operating fluid.
•
Neutralizing agent compatible with the material, the conveyed product and the operating fluid, if
applicable.
Equipment for the operation
•
Bucket
•
Filling funnel
✓
The vacuum pump is stationary.
✓
The operating fluid is drained.
✓
The drain fitting / connection is open.
•
Perform descaling.
•
Fill the descaling agent through the drain connection of the vacuum pump.
•
Close the drain connection.
•
Allow the descaling agent to take effect according to the manufacturer's instructions.
•
Rinse the descaling agent with cold water.
•
Neutralize if necessary.
•
Fill the vacuum pump with neutralizing agent through the drain connection.
•
Close the drain connection.
•
Allow the neutralizing agent to take effect according to the manufacturer's instructions.
•
Rinse the neutralizing agent with cold water.
•
Rinse the vacuum pump with cold water until no residues remain.
Disinfect
Aggressive cleaning and rinsing agents.
Pump/pump unit damage.
➢
Determine the type and duration of cleaning according to the sealing and housing
materials used.
Staff: Adjuster Mechanic
Consumable
•
Cleaning agent compatible with the material, the conveyed product and the operating fluid.
•
If necessary, disinfectant compatible with the material, the conveyed product and the operating fluid.
✓
The vacuum pump is stationary.
✓
The operating fluid is drained.
✓
The drain fitting / connection is open.
•
Perform washing.
•
Rinse the vacuum pump with hot cleaning agent (max. 100°C and 3 bar).
•
Allow the vacuum pump to cool down to room temperature.
•
Rinse the cleaning agent with cold water.
•
Disinfect the vacuum pump if necessary.
•
Rinse the vacuum pump with neutralizing agent via the drain connection.
•
Rinse the disinfectant with cold water.