General installation and maintenance instructions
SCROLL ENCLOSURE AIR COMPRESSOR
Page 13 / 22
09/2007
Manual N° 5.18396. VERSION 0 - GB
SECTION 10. MAINTENANCE SCHEDULE
Operating Hours
Item
Action Needed
500
2500
5000
10 000 20 000 Remarks
Intake Filter
Clean, replace
•
▲
Every 500 hours or less
Ventilation Screen
Clean
•
Every 500 hours or less
Air End/Blower Fan
Clean
•
Every 500 hours or less
Fan Duct
Clean
•
Every 500 hours or less
Compressor Fins
Clean
•
Every 500 hours or less
Compressor
Grease
▲
▲
(pump)
Use genuine MIL'S grease
(Every 5000 hours for high pressure models)
Tip Seal
Replace
▲
(Every 5000 hours for high pressure models)
Dust Seal
Inspect, replace
▲
(Every 5000 hours for high pressure models)
V-belt
Inspect, replace
*
•
▲
* Readjust
Temperature Sensor
•
Confirm operation
Pressure Sensor
Confirm operation
•
Magnetic Starter
Inspect
•
Replace if contact points deteriorated
Check valve
Replace
▲
Safety Valve
Confirm operation
•
Every 500 hours or less
Ventilation Fan
Inspect
•
Replace if malfunctions
Pulley
Inspect groove
•
Repair if abnormal wear is detected
Motor
Inspect
•
•
Replace if abnormal noise is detected
Intake hose
Replace
▲
Air Hose
Inspect, replace
•
▲
After Cooler
Clean outside
•
Every 500 hours or less
O-ring
Replace
▲
Operating Panel
Inspect monitor
display
Daily
Piping
Inspect for leakage
•
•
Inspect
▲
Replace
Notes:
1 - Inspect and perform maintenance periodically according to maintenance schedule.
2 - The maintenance schedule relates to the normal operation conditions. If the circumstances and load condition are
adverse, shorten the cycle time and perform maintenance accordingly.
3 - *Marked “Readjust” means the tension of the V-belt should be adjusted during the initial stage and inspected every
2,500 hours afterwards.
Chart 16