B2T2008007: Do not exceed 160° Fahrenheit (71° Celsius) water
temperature. Excessive temperature can damage the water valves
in this machine. Eliminate water hammer on the water lines to this
machine. Water hammer can rupture the water inlet valves on this
machine. Follow applicable codes when installing water hammer
arresters. Maintain incoming water pressure between 10 and 75
psi (between 0.7 and 5.1 bar). Pressures outside this range can
damage the water valves in this machine.
B2T2018004: Install 8 anchor bolts. Remove vibration switch re-
straint. (USED ONLY ON MWR36J4.)