Motor Maintenance
PELLERIN MILNOR CORPORATION
Figure 1: Typical Data Plate on a Motor
1. Find the frame code and RPM on the motor data plate. Example:
Frame code = 215T, RPM = 1725
2. Find the standard interval in
Table 1
. Example:
Standard interval = 12,000 hours
3. Find the rating and multiplication number in
Table 2
for your worst operation condition.
Example: ambient temperature = 102°F (39°C). Moderate contamination.
Rating = bad, Multiplication number = 0.5
4. Calculate the correct interval (the number of hours of operation before it is necessary to add
grease). Example:
12,000 x 0.5 = 6,000 hours
Where:
12,000 is the standard interval
0.5 is the multiplication number for a rating = bad.
5. Find the quantity of grease for the frame code for your motor in Table 3. You can use the
bearing data in the table to do maintenance. Do not use this data to adjust the quantity of
grease. Example:
grease volume = 0.16 ounces (4.7 grams)
grease gun cycles = 2.5
42
Summary of Contents for MWT12E5
Page 2: ......
Page 38: ......
Page 39: ...Service and Maintenance 1 35 ...
Page 57: ...Drive Assemblies 2 53 ...
Page 63: ...Bearing Assemblies 3 59 ...
Page 68: ......
Page 69: ...Shell and Door Assemblies 4 65 ...
Page 84: ......
Page 85: ...Control and Sensing 5 81 ...
Page 93: ...Chemical Supply 6 89 ...
Page 101: ...Water and Drain 7 97 ...
Page 108: ......
Page 109: ...Dimensional Drawings 8 105 ...
Page 110: ......
Page 111: ...107 ...
Page 112: ...108 ...
Page 113: ...109 ...
Page 114: ...110 ...
Page 115: ...111 ...
Page 116: ...112 ...
Page 117: ...113 ...
Page 118: ......
Page 119: ...115 ...
Page 120: ...116 ...
Page 121: ...117 ...