Service Connections
PELLERIN MILNOR CORPORATION
4.
Piped Outlets
Table 2: Piped Outlets for MCR09E5, MCR12E5, MCR18E5 and MWR09E5, MWR12E5, MWR18E5 models
Model
Connection
Description
Destination Requirements or
Description
Piping Specifications
MCR09E5,
MCR12E5,
MWR09E5,
and MWR12E5
Drain
2" ID hose connection
Rubber hose, PVC or other approved
material per plumbing code
Suds Overflow
2" ID hose connection
Per code
MCR18E5 and
MWR18E5
Drain
3" OD hose connection
Rubber hose, PVC or other approved
material per plumbing code
Suds Overflow
2" OD hose connection
Per code
5.
Power Connections and Precautions
WARNING 3 : Electrocution and Electrical Burn Hazards
—Contact with electric power
can kill or seriously injure you. Electric power is present inside the cabinetry unless the main
machine power disconnect is off.
• Do not service the machine unless qualified and authorized. You must clearly understand
the hazards and how to avoid them.
Notice 4 : Machine Damage
—Voltage fluctuations of more than 10% above or below the
specified voltage for your machine can damage electrical components, especially motors.
• Any such conditions should be corrected prior to commissioning your machine.
1. Electrical connections must be made by a competent electrician.
2. Machine must be grounded by connecting to a grounded metal, permanent wiring system, or
an equipment-grounding conductor must be run with the circuit conductors and connected to
the equipment-grounding terminal on the machine.
3. Stinger leg, if any, must be connected to terminal L3, never to terminals L1 or L2.
4. Make power connections within junction boxes on the rear of the machine.
5. Verify motor rotation (
Figure 1
). See the operating and trouble shooting manual for more
information. If the cylinder turns in the wrong direction, interchange the wires connected to
L1 and L2. Never move L3 under any circumstances. All motors are phased for proper
rotation. Never attempt to reconnect motors or the motor control devices.
6. Machines ordered for 208/240 volt operation are shipped set for 240 volt operation from the
factory (
Figure 2
). If the supply voltage is 208 volts, then remove the top, and place the line
voltage switch in the 208 volt position.
Summary of Contents for MCR12E5
Page 29: ...Section 1 Service and Maintenance ...
Page 46: ......
Page 47: ...Section 2 Drive Assemblies ...
Page 51: ...Section 3 Bearing Assemblies ...
Page 56: ......
Page 57: ...Section 4 Shell and Door Assemblies ...
Page 70: ......
Page 71: ...Section 5 Control and Sensing ...
Page 79: ...Section 6 Chemical Supply ...
Page 89: ...Section 7 Water and Drain ...
Page 97: ...Section 8 Dimensional Drawings ...
Page 98: ......
Page 99: ......
Page 100: ......
Page 101: ......
Page 102: ......
Page 103: ......
Page 104: ......
Page 105: ......
Page 106: ......
Page 107: ......
Page 108: ......
Page 109: ......
Page 110: ......
Page 111: ......