R
Pellerin
Milnor
Corporation
Pellerin
Milnor
Corporation
P.
O.
Box
400,
Kenner
,L
A
70063-0400
Litho
in
U.S.A.
BMP960052/97126V
(Sheet
1
of
2)
Pneuma
tic
Sc
hema
tic
72072T
G1
BMP960052/97126V
(1
of
2)
TO
BLOWER
WHEEL/BLOW
OFF
(IF
NO
AUT
OLINT)
TO
BLOW
DOWN
(IF
AUT
OLINT)
AIR
80-100
PSI
1
2
3
NORMALL
Y
CLOSED PILOT VA
LV
E
NORMALL
Y
CLOSED PILOT VA
LV
E
NORMALL
Y
CLOSED PILOT VA
LV
E
NORMALL
Y
CLOSED PILOT VA
LV
E
NORMALL
Y
CLOSED PILOT VA
LV
E
NORMALL
Y
CLOSED PILOT VA
LV
E
NORMALL
Y
CLOSED PILOT VA
LV
E
NORMALL
Y
CLOSED PILOT VA
LV
E
NORMALL
Y
CLOSED PILOT VA
LV
E
NORMALL
Y
CLOSED
PILOT VA
LV
E
EXHAUST
EXHAUST
EXHAUST
EXHAUST
EXHAUST
EXHAUST
EXHAUST
EXHAUST
EXHAUST
EXHAUST
6
8
10
6
5
4
6
6
66
6
6
6
9
9
7
BLOWER
DAMPER
LOAD
DOOR
OPTIONAL
AUT
OLINT
FLAG
DOWN
HINGED
UNLOAD
DOOR
NON-HINGED
(CONVEYOR
DISCHARGE)
&
DENIM
DISCHARGE
UNLOAD
DOOR
(USED
WITH
SHUTTLES)
PRESSURE
IS
APPLIED
TO
ACTUA
TO
R
TO
OPEN
LOAD
DOOR
WHEN
PILOT
IS
ENERGISED
SHUTTLE
VA
LV
E
HOLDS
AIR
PRESSURE
TO
PREVENT
DOOR
OPENING
IF
POWER
IS
LOST
.
SEE NOTES (1-4)
SEE NOTES (1-4)
PRESSURE
IS
APPLIED
TO
ACTUA
TO
RS
TO
OPEN
DAMPERS
AND
FIL
TER
DOOR
TO
ST
AR
T
LINT
REMOV
AL
PRESSURE
IS
APPLIED
TO
ACTUA
TORS
TO
CLOSE
DAMPERS
AND
FIL
TER
DOOR
WHEN
NO
LINT
REMOV
AL
PRESSURE
IS
APPLIED
TO
AIR-ON ACTUA
TO
R
O
N
SHUTTLE
RAIL
TO
ST
OP
SHUTTLE
IN
FRONT
OF
DR
YER
WHEN
PILOT
IS
ENERGISED.
CLOSED/OPEN
CLOSED/OPEN
OPEN/CLOSED
OPEN/CLOSED
OPEN/CLOSED
CLOSED/OPEN
OPEN/CLOSED
INLET
DAMPER
FIL
TER
DOOR
OUTLET DAMPER
TO
P
CYLINDER
BOTT
OM
CYLINDER
TANK
HOLDS
AIR
PRESSURE
TO
PREVENT
UNLOAD
DOOR
FROM
OPENING
AND
DUMPING
GOODS
IF
POWER
IS
LOST
PRESSURE
IS
APPLIED
TO
ACTUA
TO
R
TO
OPEN
UNLOAD
DOOR
W
HEN
PILOT
IS
ENERGISED
PRESSURE
IS
APPLIED
TO
ACTUA
TO
R
TO
CLOSE
UNLOAD
DOOR
WHEN
PILOT
IS
ENERGISED
PRESSURE
IS
APPLIED
TO
ACTUA
TO
R
TO
OPEN
UNLOAD
DOOR
WHEN
PILOT
IS
ENERGISED
PRESSURE
IS
APPLIED
TO
ACTUA
TOR
TO
CLOSE
UNLOAD
DOOR
WHEN
PILOT
IS
ENERGISED
SHUTTLE
VA
LV
E
HOLDS
AIR
PRESSURE
TO
PREVENT
DOOR
OPENING
IF
POWER
IS
LOST
SHUTTLE
VA
LV
E
HOLDS
AIR
PRESSURE
TO
PREVENT
DOOR
OPENING
IF
POWER
IS
LOST
MINIMUM
AIR
FLOW
OCCURS
WHEN
PRESSURE
IS
APPLIED
TO
ALL
BLOWER
DAMPER
AIR
CYLINDER
ACTUA
TORS.
MORE
THAN
MINIMUM
AIR
FLOW
OCCURS
WHEN
PRESSURE
IS
APPLIED
ONL
Y
TO
THE
3"
BLOWER
DAMPER
AIR
CYLINDER
ACTUA
TOR.
LESS
THAN
MAXIMUM
AIR
FLOW
OCCURS
WHEN
PRESSURE
IS
APPLIED
ONL
Y
TO
THE
2"
BLOWER
DAMPER
AIR
CYLINDER
ACTUA
TOR.
MAXIMUM
AIR
FLOW
OCCURS
WHEN
NO
PRESSURE
IS
APPLIED
TO
ACTUA
TORS.
STRAINER
MUST
BE
CLEANED,
SEE
PREVENT
ATIVE
MAINTENANCE
CHECKLIST
FOR
SCHEDULE
USED
ONL
Y
WITH
OPTIONAL
AUT
OLINT
NOTES:
1.
2.
3.
4.
114
Summary of Contents for 72072
Page 6: ...2 ...
Page 21: ...Section 1 Service and Maintenance 17 ...
Page 51: ...Section 2 Covers and Shipping Brackets 47 ...
Page 57: ...Section 3 Machine Housing Assemblies 53 ...
Page 65: ...Section 4 Drive Assemblies 61 ...
Page 79: ...Section 5 Door Assemblies 75 ...
Page 87: ...Section 6 Denim Processing 83 ...
Page 97: ...Section 7 Gas Piping and Assemblies 93 ...
Page 110: ...106 ...
Page 111: ...Section 8 Water and Steam Piping and Assemblies 107 ...
Page 117: ...Section 9 Pneumatic Piping and Assemblies 113 ...