Chapter 1. Controls
PELLERIN MILNOR CORPORATION
• Do not tamper with or disable any safety device or operate the machine with a
malfunctioning safety device. Request authorized service.
Jog direction switch (
J
/
j
)
—allows you to jog the cylinder slowly in either direction to help in
loading or unloading the machine. To jog the cylinder clockwise, hold the jog direction switch
to the left (
J
) while pressing the door open button.
Door hydraulic circuit pressure gauge
—on the rear panel of the machine, this gauge displays
the pressure in the hydraulic circuit when the door is opening and closing. During normal
operation, this gauge registers 0 unless the hydraulic door opening or closing. When the door
is moving, this gauge indicates about 900 psi (62 bar) when the hydraulic system is properly
adjusted.
1.1.5.
What does this Switch do?
Other buttons and switches are used to control additional standard and optional machine
functions. These miscellaneous controls are located and described in this section.
Mildata/Local selector switch (
Figure 6
)
—located on the microprocessor control box (see
Figure 1
), allows the machine to communicate with a Mildata network. A Mildata network
connects several machines together and allows them to share wash formulas and other data
with the Mildata computer. When this switch is in the
Mildata
position (
-
) and you enter a
formula number, the machine requests the contents of the formula from the Mildata computer.
When set to the
Local
position (
_
), only formulas present
in the machine
are available.
Figure 6: Mildata/Local Selector switch
Manual supply flush button (
Figure 7
)
—On machines equipped with an optional flushing
supply injector, press this button to spray water into the supply injector to flush any remaining
chemicals into the cylinder. If you manually add supplies during a wash formula, press this
button to flush any remaining undiluted chemicals out of the supply chute. If the machine is
not equipped with the optional supply injector, press this button to flush the liquid chemical
inlets with fresh water.
Figure 7: Manual Supply Flush button
Autospot selector switch (
Figure 8
)
—Some divided-cylinder machines are equipped with the
Autospot
feature to aid in loading and unloading. This optional feature optimally positions the
basket for access to the selected pocket.