Chapter 4. Troubleshooting
PELLERIN MILNOR CORPORATION
4.2.2.
Inputs
Table 14: Input Function and Connection
Label
Function
Connection
IN-0
Door is closed
M6-1
IN-1
Low level achieved (reserved)
M6-2
IN-2
High level achieved (reserved)
M6-3
IN-3
Vibration switch tripped
M6-4
IN-4
Inverter input
M6-5
IN-5
Door open desired
M6-6
IN-6
Brake is off
M6-11
IN-7
External fault
M6-12
IN-8
Timer stop
M7-6
IN-9
Front is not down (reserved)
M7-7
IN-10
Speed limit desired (reserved)
M7-13
IN-11
(reserved)
M7-14
IN-12
(reserved)
M6-7
IN-13
(reserved)
M6-8
IN-14
(reserved)
M6-9
IN-15
Cancel operator signal (reserved)
M6-10
IN-16
(reserved)
M7-2
IN-17
(reserved)
M7-9
IN-18
(reserved)
M7-3
IN-19
(reserved)
M7-10
IN-20
(reserved)
M7-4
IN-21
(reserved)
M7-11
IN-22
(reserved)
M7-5
IN-23
(reserved)
M7-12
Figure 34: Input Indicator Position and Label
— End of BICLUT01 —
BICLJT01 (Published) Book specs- Dates: 20170804 / 20170804 / 20170804 Lang: ENG01 Applic: CLJ
4.3. Components of the MilTouch
™
Controller Circuit Boards
Use this document to identify components when troubleshooting. Consult with the Milnor factory
before you make any attempt to repair or replace individual components.
47
Summary of Contents for 30015V8Z
Page 2: ......
Page 4: ......
Page 5: ...English 1 1 ...
Page 6: ......
Page 61: ...Deutsch 2 57 ...
Page 62: ......
Page 118: ......
Page 119: ...Français 3 115 ...
Page 120: ......
Page 180: ......
Page 181: ...Nederlands 4 177 ...
Page 182: ......
Page 235: ...Ελληνική 5 231 ...
Page 236: ......
Page 291: ...Español 6 287 ...
Page 292: ......