Specifications
Specifications
Process Application:
{
liquids and slurries
{
Measurement Range
{
0.3 to 5m (1 to 15 ft) typical
(may depend on application variables)
{
Vessel Pressure
{
vented to atmosphere
Operation:
{
Beam Angle
{
10°
{
Frequency
{
43 KHz
{
Temperature Sensor
{
internal
{
Supply Source
{
transducer shall only be supplied by Milltronics
certified controller
Environmental
:
{
Location
{
indoor / outdoor
{
Ambient temperatures
{
-20 to 65 °C (-4 to 149 °F)
{
Altitude
{
2000 m maximum
{
Pollution degree
{
4
Construction:
{
Housing
{
Kynar Flex
®1
body and Hypalon
2
face
{
Mounting
{
1” NPT conduit connection
Cable:
{
2 wire shielded / twisted, 0.5 mm
2
(18 AWG) PVC jacket
Ingress protection:
{
IP-68
Weight
3
:
{
1.2 Kg (2.6 lb)
Options
:
{
factory flanged to suit ANSI , DIN or JIS standard
{
split flange (field mount) to suit ANSI, DIN or JIS standard
{
submergence shield (flooding applications)
Cabling (maximum run):
{
365 m (1200 ft) using RG-62 A/U coaxial cable
{
365 m (1200 ft) using 2-wire twisted pair / braided and foil shielded 20
AWG (0.5 mm
2
), PVC jacket (EnviroRanger ERS 500 only)
Approvals
:
{
CE
4
, CSA, FM, CENELEC, ATEX, see device nameplate
1
Kynar Flex
®
is registered trade mark of ELF Atochem.
2
Hypalon
®
is a registered trademark of Du Pont
3
approximate weight of transducer with standard cable length
4
EMC performance available upon request
Summary of Contents for PL-590
Page 1: ...Instruction Manual PL 590 XRS 5 Transducer ...
Page 4: ...Page 4 XRS 5 Transducer PL 590 ...
Page 6: ...Page 6 XRS 5 Transducer PL 590 Specifications ...
Page 10: ...Page 10 XRS 5 Transducer PL 590 Installation ...
Page 18: ...Page 18 XRS 5 Transducer PL 590 Applications ...
Page 21: ...PL 590 XRS 5 Transducer Page 21 Installation Diagram Installation Diagram ...
Page 22: ...Page 22 XRS 5 Transducer PL 590 Installation Diagram ...