![Milltronics PL-590 Instruction Manual Download Page 11](http://html1.mh-extra.com/html/milltronics/pl-590/pl-590_instruction-manual_1797011011.webp)
PL-590
XRS-5 Transducer
Page 11
Mounting
Mounting
Recommendations
•
Mount the transducer so that it is
above the maximum material level by more
than the blanking value
to ensure that accurate results are achieved. Refer
to the associated transceiver manual for information on setting the blanking
value.
•
The transducer must be mounted so that the axis of transmission is
perpendicular to the liquid’s surface.
•
Do not over tighten mounting.
Hand tightening of the mounting hardware is
sufficient.
•
Consider
the
optional
temperature sensor
when mounting the transducer.
Suspended Conduit
Bracket
Flexible conduit transducer should not be
subjected to wind, vibration or jarring.
Submersible
Plywood
Submersible transducer, used in
applications where flooding is possible.
Plywood mounting provides excellent
isolation, but must be rigid enough to
avoid flexing if subjected to loading.
rigid metal
conduit
coupling
transducer
rigid metal
conduit
submergence
shield
flexible conduit
steel channel
coupling
coupling
coupling
Summary of Contents for PL-590
Page 1: ...Instruction Manual PL 590 XRS 5 Transducer ...
Page 4: ...Page 4 XRS 5 Transducer PL 590 ...
Page 6: ...Page 6 XRS 5 Transducer PL 590 Specifications ...
Page 10: ...Page 10 XRS 5 Transducer PL 590 Installation ...
Page 18: ...Page 18 XRS 5 Transducer PL 590 Applications ...
Page 21: ...PL 590 XRS 5 Transducer Page 21 Installation Diagram Installation Diagram ...
Page 22: ...Page 22 XRS 5 Transducer PL 590 Installation Diagram ...