Millipore Elix Essential 10 User Manual Download Page 25

System 

Elix® Essential 3, 5, 10, 15 (UV) / RiOs™ Essential 5, 8, 16, 24 

23 

Software navigation map 

The software map below shows the main menus available in the system. 
 

 

Standby or maintenance 

Ready or Tank Filling 

Press 

  

to navigate… 

Press 

  

to navigate… 

Summary of Contents for Elix Essential 10

Page 1: ...User Manual Elix Essential 3 5 10 15 UV RiOs Essential 5 8 16 24...

Page 2: ......

Page 3: ...any questions or requests please use the contact information provided below By Internet The Internet site can be used to find addresses telephone fax numbers and other information Internet Site Addre...

Page 4: ...DANGER sticker is used to refer to a position on the water system Cabinet or inside of it that could be hazardous This ELECTRICAL GROUND sticker is used to refer to a position on the water system Cab...

Page 5: ...tions and functions of the water system A quick guide that describes quick access to maintenance and operating information It may be necessary for to reference these documents for maintenance or other...

Page 6: ...tem name and type 6 Electrical connections 2 Display and keypad 7 System s hydraulic connections 3 Progard Pretreatment Pack location 8 System ID and serial number 4 Locking handle 9 External power su...

Page 7: ...3 VALIDATE key This button is used to confirm a change or an action required by the water system It is also used to save any changes made in configuration 4 HELP INDICATOR icon There are up to 3 of t...

Page 8: ......

Page 9: ...Table of contents...

Page 10: ...p 23 Consumables replacement 25 Replacing Progard Pack 26 Sanitization and cleaning 29 Sanitizing RO membranes with chlorine 30 Cleaning RO membranes with acid base pH 31 Other functions 33 Saving dis...

Page 11: ...Elix Essential 3 5 10 15 UV RiOs Essential 5 8 16 24 9 Item catalog numbers 49 Consumables catalog numbers 50 Optional consumables catalog numbers 50 Optional equipment catalog numbers 51 System s ca...

Page 12: ......

Page 13: ...Items needed...

Page 14: ...list Verify that all items are available before beginning the installation See the Content list for more details Water system unit A User manual and Quick Reference Guide B External power supply C Pro...

Page 15: ...view instantaneously quality data through their internet browser for rapid monitoring of his water purification system Millitrack Software users have also real time remote access to interactive web p...

Page 16: ......

Page 17: ...System...

Page 18: ...e System sanitization is required Product water resistivity is below set point Low feed water pressure is detected Water is detected if water sensor installed Contact Millipore Item Description 3 Valu...

Page 19: ...order a new Progard pack Yellow color display and the Progard pack must be changed Product water resistivity is 15 M cm Yellow color display and the CL2 cleaning must be started Product water resistiv...

Page 20: ...of operating status TANK FILLING The tank is being filled with EDI or RO water A sensor starts and stops this mode FLUSH A periodic flush of the RO portion of the system is done This refreshes the wa...

Page 21: ...be performed SAN In this view the system s sanitization can be performed by a qualified service representative LF 02 In this view the UV Lamp 254 nm lifetime can be reset once it has been changed by...

Page 22: ...t of ions entering it SP 03 Set point for the resistivity or conductivity for product water Below this set point an alarm is indicated DATE Menu where date and time can be adjusted IP AD used with Mil...

Page 23: ...BY mode Press on right arrow 2 In maintenance menu press 3 Press on right arrow until the date menu is displayed 4 Press to enter dAtE menu 5 Change year with arrows and press 6 Change month with arro...

Page 24: ...re value can be displayed by pressing RO pump pressure value can be displayed by pressing RO rejection value can be displayed by pressing On Elix Essential RO permeate water conductivity value can be...

Page 25: ...ial 3 5 10 15 UV RiOs Essential 5 8 16 24 23 Software navigation map The software map below shows the main menus available in the system Standby or maintenance Ready or Tank Filling Press to navigate...

Page 26: ......

Page 27: ...Consumables replacement...

Page 28: ...the pack Note it is recommended to replace the Vent Filter at this time Additionally it is recommended to clean the feed water strainer Removing exhausted pack Verify or put the system in Standby by...

Page 29: ...s are push inside against the inner edge of the ports 1 Mount the bottom of the Pack onto the small hole in the cabinet Swing the rest of the Pack so that the top of the Pack aligns with pack locking...

Page 30: ......

Page 31: ...Sanitization and cleaning...

Page 32: ...the RO membrane When the system shows the yellow alert put the system in Standby by pressing 1 Using the tool unscrew the sanitation port cap 2 Remove the plug and insert the tablet in the port 3 Scr...

Page 33: ...pressing 1 Using the tool unscrew the sanitation port cap 2 Remove the plug and insert the tablet in the port 3 Screw the plug back make sure the o ring is in place Note do not use the tool to screw...

Page 34: ......

Page 35: ...Other functions...

Page 36: ...stem s display backlight after a 15 min period of non use The ECO mode is disabled by pressing a keypad button or when a warning message is displayed by the system error code or warning symbol Configu...

Page 37: ...ime and date can be lost as a result If the system is shut off for a long period of time contact your service representative If required empty the tank using the front valve 1 Insert one end of the tu...

Page 38: ......

Page 39: ...Error messages...

Page 40: ...e temperature max Contact your service representative Er 09 RO permeate conductivity min Contact your service representative Er 10 RO permeate conductivity max Contact your service representative Er 1...

Page 41: ...or is well adjusted or is working properly if installed Water leak is detected Er 02 Feed water temperature 35 C Verify that the feed water temperature is really greater than 35 C See the feed water q...

Page 42: ......

Page 43: ...Chemical and technical specifications...

Page 44: ...h tubing 6 m Product water flow rates Elix Essential 3 UV system 3 L h Elix Essential 5 UV system 5 L h Elix Essential 10 UV system 10 L h Elix Essential 15 UV system 15 L h RiOs Essential 5 system 5...

Page 45: ...ption 150 W Elix RiOs input 24 VDC 6 25 A Environmental requirements Altitude 2000 m Ambient operating temperature 5 40 C Ambient storage temperature 5 40 C Installation category I Pollution degree 2...

Page 46: ......

Page 47: ...Legal information...

Page 48: ...when it leaves the water purification system provided that it s fed with water quality within specifications and properly maintained as required by the supplier We do not warrant these systems for an...

Page 49: ...t or its packaging indicates that the product should not be treated like household waste when discarded Instead the product should be disposed of at a location that handles discarded electric or elect...

Page 50: ......

Page 51: ...Item catalog numbers...

Page 52: ...ION TABLETS US only Chlorine tablets 24 per pack 5874316024 SANITIZATION TABLETS Canada only Chlorine tablets 24 per pack 5874316024C RO ACID CLEANER Acid pouch 12 per pack ZWACID012 RO BASE CLEANER B...

Page 53: ...display splitter ZSTWINLX2 ASM 2011 Automatic sanitization module TANKASMES WATER SENSOR Water leak detector ZFWATDET4 WALL MTG BRACKET System wall mounting bracket SYSTFIX01 EXTERNAL RELAY KIT Alert...

Page 54: ...Elix Essential 3 5 10 15 UV RiOs Essential 5 8 16 24 FTPF12381 V2 0 04 2012...