OM-278618 Page 26
SECTION 6 − OPERATION
6-1.
Front Panel Controls
Ref. 278547-A / Ref. 278649-A
3
4
13
Weld process operation sections de-
scribe functionality of the identified items
(See Sections 7-3 thru 9-3).
1
Remote 14 Receptacle
2
Remote In Use Indicator
3
Left Display
4
Right Display
The meters display the actual weld output
values after arc initiation and remains dis-
played for approximately three seconds
after the arc is broken.
5
Adjust Control
6
Volts Indicator
7
Arc Control Indicator For Wire Modes
8
Amps Indicator
9
Arc Control Indicator For Stick Modes
10 Arc Control Stiff Indicator
11 Arc Control Soft Indicator
12 Arc Control Button
13 Mode Switch
14 Weld Output Terminal (+)
15 Optional Gas Valve Knockout
16 Weld Output Terminal (−)
17 Power Switch
14
15
16
9
8
7
6
11
10
12
2
1
5
17