Complete Parts List available at www.MillerWelds.com
OM-258900 Page 39
7-3. Optional Excel Power
Excel power option provides gener-
ator power at idle speed and while
welding. This allows most job site
tools to operate properly at engine
idle speed.
!
Use GFCI protection when
operating auxiliary equip-
ment. If unit does not have
GFCI receptacles, use GFCI-
protected extension cord. Do
not use GFCI receptacles to
power life support equip-
ment.
1
120 V 20 A AC Excel Power
Receptacle
This receptacle supplies 2.4 kVA/
kW of pure 120 V, 60 Hz sine wave
power at ALL engine speeds.
Circuit protection is provided by
CB3 only; CB1 does not provide
protection to Excel power.
Combined output of all receptacles
limited to peak rating of the genera-
tor.
Ref. 248 009 / 250 717-C
ALL
Speeds
60Hz
Run Tools at Idle Speed
Excel power
1
7-4. Simultaneous Weld And Power
Weld Current in Amperes
Total Power in Watts
120 V Full kVA Receptacle
Amperes
240 V Full kVA Receptacle
Amperes
250
2200
18
9
180
3500
29
14
125
5200
43
21
90
8000
66
33
0
12,000 (Peak)
88
44