OM-246 011 Page 18
4-9. Terminal Strip TE1, TE2 and Remote 14 Receptacle RC7 Information
Socket
on RC7
Terminal
on TE2
Terminal
on TE1
Information
24 VOLTS AC
A
−
−
24 volts, 12 amperes, AC. Protected by circuit breaker
CB2.
B
−
−
Contact closure to A completes 24 volts AC contactor
control circuit.
REMOTE OUTPUT CONTROL
C
−
−
Command reference; +10 volts DC.
D
−
−
Remote control circuit common.
E
−
−
0 to +10 volts DC input command signal from remote
control.
115 VOLTS AC
I
−
−
115 volts, 12 amperes AC. Protected by circuit breaker
CB1.
J
−
−
Contact closure to I completes 115 volts AC contactor
control circuit.
GND
K
G
−
−
−
−
Chassis common.
Circuit common for 24 and 115 volts AC circuits.
A/V
AMPERAGE
VOLTAGE
F
−
−
Current feedback; +1 volt DC per 100 amperes.
H
−
−
Voltage feedback; +1 volt DC per 10 output terminal
volts.
REMOTE VOLTAGE SENSING
*
N
−
Voltage sensing signal from Work weld output terminal.
*
P
−
Voltage sensing signal from Electrode weld output
terminal.
−
TP
−
Test Point
−
−
A
Used for synchronizing multiple AC arcs.
−
−
C
Used for synchronizing multiple AC arcs.
−
−
E
Used for synchronizing multiple AC arcs.
* Not Used,
−
Not Applicable
2
A
J
B
K
I
C
L
N
H
D
M
G
E
F
1
5
!
Turn Off welding power
source before opening ac-
cess door.
1
Access Door
2
Remote 14 Receptacle
(Mounted Inside Access Area)
3
Terminal Strip TE2
4
Terminal Strip TE1
5
Remote Control
Connect remote control to Remote
14 receptacle.
3
4
247 476-C
Summary of Contents for Subarc AC/DC 1000
Page 14: ...OM 246 011 Page 10...
Page 39: ...OM 246 011 Page 35 244 959 C...
Page 40: ...OM 246 011 Page 36 Figure 8 2 Circuit Diagram For Sub Arc AC DC 1250 400 V Input Model...
Page 41: ...OM 246 011 Page 37 247 290 D...
Page 48: ...Notes...
Page 49: ...Notes...
Page 50: ...Notes...