background image

OM-238 428 Page 1

SECTION 1 

 SAFETY PRECAUTIONS - READ BEFORE USING

som _2007

04

7

Protect yourself and others from injury — read and follow these precautions.

1-1. Symbol Usage

DANGER! 

 Indicates a hazardous situation which, if

not avoided, will result in death or serious injury. The

possible hazards are shown in the adjoining symbols

or explained in the text.

Indicates a hazardous situation which, if not avoided,

could result in death or serious injury. The possible

hazards are shown in the adjoining symbols or ex-

plained in the text.

NOTICE

 

 Indicates statements not related to personal injury.

.

Indicates special instructions.

This group of symbols means Warning! Watch Out! ELECTRIC

SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult sym-

bols and related instructions below for necessary actions to avoid the

hazards.

1-2. Arc Welding Hazards

The symbols shown below are used throughout this manual

to call attention to and identify possible hazards. When you

see the symbol, watch out, and follow the related instructions

to avoid the hazard. The safety information given below is

only a summary of the more complete safety information

found in the Safety Standards listed in Section 1-5. Read and

follow all Safety Standards.

Only qualified persons should install, operate, maintain, and

repair this unit.

During operation, keep everybody, especially children, away.

ELECTRIC SHOCK can kill.

Touching live electrical parts can cause fatal shocks

or  severe burns. The electrode and work circuit is

electrically live whenever the output is on. The input

power circuit and machine internal circuits are also

live when power is on. In semiautomatic or automatic wire welding, the

wire, wire reel, drive roll housing, and all metal parts touching the

welding wire are electrically live. Incorrectly installed or improperly

grounded equipment is a hazard.

D

Do not touch live electrical parts.

D

Wear dry, hole-free insulating gloves and body protection.

D

Insulate yourself from work and ground using dry insulating mats

or covers big enough to prevent any physical contact with the work

or ground.

D

Do not use AC output in damp areas, if movement is confined, or if

there is a danger of falling.

D

Use AC output ONLY if required for the welding process.

D

If AC output is required, use remote output control if present on

unit.

D

Additional safety precautions are required when any of the follow-

ing electrically hazardous conditions are present: in damp

locations or while wearing wet clothing; on metal structures such

as floors, gratings, or scaffolds; when in cramped positions such

as sitting, kneeling, or lying; or when there is a high risk of unavoid-

able or accidental contact with the workpiece or ground. For these

conditions, use the following equipment in order presented: 1) a

semiautomatic DC constant voltage (wire) welder, 2) a DC manual

(stick) welder, or 3) an AC welder with reduced open-circuit volt-

age. In most situations, use of a DC, constant voltage wire welder

is recommended. And, do not work alone!

D

Disconnect input power or stop engine before installing or

servicing this equipment. Lockout/tagout input power according to

OSHA 29 CFR 1910.147 (see Safety Standards).

D

Properly install and ground this equipment according to its

Owner’s Manual and national, state, and local codes.

D

Always verify the supply ground 

 check and be sure that input

power cord ground wire is properly connected to ground terminal in

disconnect box or that cord plug is connected to a properly

grounded receptacle outlet.

D

When making input connections, attach proper grounding conduc-

tor first 

 double-check connections.

D

Keep cords dry, free of oil and grease, and protected from hot metal

and sparks.

D

Frequently inspect input power cord for damage or bare wiring 

replace cord immediately if damaged 

 bare wiring can kill.

D

Turn off all equipment when not in use.

D

Do not use worn, damaged, undersized, or poorly spliced cables.

D

Do not drape cables over your body.

D

If earth grounding of the workpiece is required, ground it directly

with a separate cable.

D

Do not touch electrode if you are in contact with the work, ground,

or another electrode from a different machine.

D

Do not touch electrode holders connected to two welding ma-

chines at the same time since double open-circuit voltage will be

present.

D

Use only well-maintained equipment. Repair or replace damaged

parts at once. Maintain unit according to manual.

D

Wear a safety harness if working above floor level.

D

Keep all panels and covers securely in place.

D

Clamp work cable with good metal-to-metal contact to workpiece

or worktable as near the weld as practical.

D

Insulate work clamp when not connected to workpiece to prevent

contact with any metal object.

D

Do not connect more than one electrode or work cable to any

single weld output terminal.

SIGNIFICANT DC VOLTAGE exists in inverter-type

welding power sources after removal of input

power.

D

Turn Off inverter, disconnect input power, and discharge input

capacitors according to instructions in Maintenance Section

before touching any parts.

HOT PARTS can cause severe burns.

D

Do not touch hot parts bare handed.

D

Allow cooling period before working on gun or

torch.

D

To handle hot parts, use proper tools and/or

wear heavy, insulated welding gloves and

clothing to prevent burns.

Summary of Contents for RAD-100

Page 1: ...RAD 100 Description OM 238 428A 2008 04 Heavy Duty Motor For Strip Clad Feed Assemblies Motor Assembly Visit our website at www MillerWelds com File SUBMERGED SAW...

Page 2: ...tinue the tradition They re just as committed to providing equipment and service that meets the high standards of quality and value established in 1929 This Owner s Manual is designed to help you get...

Page 3: ...5 2 3 Dangers suppl mentaires en relation avec l installation le fonctionnement et la maintenance 7 2 4 Proposition californienne 65 Avertissements 8 2 5 Principales normes de s curit 9 2 6 Informatio...

Page 4: ......

Page 5: ...cramped positions such as sitting kneeling or lying or when there is a high risk of unavoid able or accidental contact with the workpiece or ground For these conditions use the following equipment in...

Page 6: ...s they are properly prepared according to AWS F4 1 see Safety Standards D Do not weld where the atmosphere may contain flammable dust gas or liquid vapors such as gasoline D Connect work cable to the...

Page 7: ...ans D Keep all doors panels covers and guards closed and securely in place D Have only qualified persons remove doors panels covers or guards for maintenance as necessary D Reinstall doors panels cove...

Page 8: ...York NY 10036 8002 phone 212 642 4900 website www ansi org Standard for Fire Prevention During Welding Cutting and Other Hot Work NFPA Standard 51B from National Fire Protection Association P O Box 91...

Page 9: ...source lectrique courant lectrique s av re n cessaire se servir de la fonction de t l commande si l appareil en est quip D D autres consignes de s curit sont n cessaires dans les condi tions suivante...

Page 10: ...de protection Le soudage effectu sur des conteneurs ferm s tel que des r servoirs tambours ou des conduites peu provoquer leur clatement Des tincelles peuven tre projet es de l arc de soudure La proje...

Page 11: ...e pour usage ult rieur D Utiliser les quipements corrects les bonnes proc dures et suffi samment de personnes pour soulever et d placer les bouteilles D Lire et suivre les instructions sur les bouteil...

Page 12: ...de provoquer des interf rences D L nergie lectromagn tique risque de provo quer des interf rences pour l quipement lec tronique sensible tel que les ordinateurs et l quipement command par ordinateur t...

Page 13: ...O Box 371954 Pittsburgh PA 15250 7954 t l phone 1 866 512 1800 il y a 10 bureaux r gionaux le t l pho ne de la r gion 5 Chicago est 312 353 2220 site Internet www osha gov 2 6 Information EMF Consid r...

Page 14: ...OM 238 428 Page 10...

Page 15: ...5 HP 2500 RPM 120 1 290 in lb 21 RPM 3 2 Description Ref 805 215 A 1 Motor This unit is a heavy duty motor de signed for automated strip clad ap plications The various strip head manufac turers have...

Page 16: ...79 C Ref 805 215A 300 474 640 in Detail A Scale 1 1 Section B B Scale 1 1 B B 750 in 188 in 1 656 in 4 425 in 1 024 in Ref 1 024 in Ref 1 448 in Ref 2 896 in Bolt Circle 5 16 in 18 UNC 2B THRD 500 in...

Page 17: ...tacle RC2 Information For Part Number 212591 REMOTE 10 Socket Socket Information Wirefeed Drive Motor Hookups A To positive motor armature 115 volts DC motor B To negative motor armature 115 volts DC...

Page 18: ...nce Disconnect power before maintaining 3 Months Replace Unreadable Labels Repair Or Replace Cracked Weld Cable Clean And Tighten Weld Terminals Cord Gas Hose Gun Cable Replace Cracked Parts 6 Months...

Page 19: ...Damaged Brushes 1 2 1 Brush Cap 2 Spring Clip 3 Brush Remove brush cap Remove spring clip and brush Replace brush if it becomes chipped or broken or if less than 3 8 in 9 5 mm of brush material is le...

Page 20: ...OM 238 428 Page 16 SECTION 5 ELECTRICAL DIAGRAM RED BROWN GREEN TACH BARE GREEN BLACK RED WHITE PLG1 4 6 7 8 9 PLG1 Motor 3 5 1 Figure 5 1 Circuit Diagram...

Page 21: ...Notes 16 Gauge 063 in 22 Gauge 031 in 24 Gauge 025 in 20 Gauge 037 in 18 Gauge 050 in 14 Gauge 078 in 1 8 in 125 in 3 16 in 188 in 1 4 in 25 in 5 16 in 313 in 3 8 in 375 in 1 2 in 5 in MATERIAL THICKN...

Page 22: ...embly Quantity 1 238 429 Motor 1 5HP 115VDC 2500 RPM 120 1 Ratio 1 2 208 089 Brush Cap Motor 1 3 208 088 Spring Motor 1 4 208 087 Brush Motor 1 5 224 161 End Shield Motor W Hall Effect Bd W Leads 1 To...

Page 23: ...ns and Subarc SAW Guns Induction Heating Coils and Blankets Cables and Non Electronic Controls APT SAF Model Plasma Cutting Torches Remote Controls Accessory Kits Replacement Parts No labor Spoolmate...

Page 24: ...retain with your personal records Always provide Model Name and Serial Style Number Contact a DISTRIBUTOR or SERVICE AGENCY near you Welding Supplies and Consumables Options and Accessories Personal...

Reviews: