OM-1326 Page 9
Return To Table Of Contents
SECTION 3 − DEFINITIONS
3-1.
Symbols And Definitions
Wire Feed
Output
X
Duty Cycle
Do Not Switch
While Welding
V
Volts
Increase
On
Off
Gas Metal Arc
Welding (GMAW)
Gun
Wire Feed Spool
Gun
Gas Input
Gas Output
Voltage Input
Press To Reset
U
0
Rated No-Load
Voltage (Average)
SECTION 4 − INSTALLATION
4-1.
Specifications
Rated Output
Max. Open-
Circuit
Amps Input at Rated Output (60% Duty Cycle), 50 or 60 Hz, Single-Phase
Rated Output
Circuit
Voltage
200 (208) V
230 V
400 V
460 V
575 V
KVA
KW
250 A at 28 VDC,
40% Duty Cycle
200 A at 28 VDC,
60% Duty Cycle
38
48
2.3*
42
2*
24
1.2*
21
1*
17
0.8*
9.8
0.46*
7.5
0.13*
Wire Type and Diameter
Wire Feed Speed
Dimensions
Net Weight
Solid Steel
Stainless Steel
Flux Cored
25−700 IPM
(.65−17.8 m/min)
H: 32 in (813 mm)
W: 19 in (483 mm)
215 lb
(98 kg)
.023 − .045 in
(0.6 − 1.2 mm)
.023 − .045 in
(0.6 − 0.9 mm)
.030 − .045 in
(0.8 − 1.2 mm)
(.65−17.8 m/min)
W: 19 in (483 mm)
D: 39 in (991 mm)
(98 kg)
* While idling
Operating Temperature Range − −20C to +40C
Storage Temperature Range − -30C to + 50C