OM-287504 Page 15
4-5. Shielding Gas Connection
Obtain gas cylinder and chain to
running gear, wall, or other station-
ary support so cylinder cannot fall
and break off valve.
1
Cylinder
2
Regulator/Flowmeter
Install so face is vertical.
3
Gas Hose Connection
Fitting has 1/4 right-hand BSP
threads. Obtain and install gas
hose.
4
Gas In Fitting
5
Gas Out Fitting
The Gas In and Gas Out fittings
have 1/4 right-hand BSP male
threads. Obtain proper size, type,
and length hose and make connec-
tions as follows:
Connect hose from shielding gas
supply regulator/flowmeter to Gas
In fitting.
Connect hose coupler to torch.
Connect one end of gas hose to
hose coupler. Connect remaining
end of gas hose to Gas Out fitting.
3
1
2
5
956172374_5-A
Tools Needed:
17 mm
4
Summary of Contents for MigMatic S400i
Page 4: ......
Page 5: ......
Page 33: ...OM 287504 Page 27 956172379 A PC5 PC5 HD1 HD2 PC1 PC8...
Page 34: ...OM 287504 Page 28 PC2 PC2 PC4 PC7 FM FM FM FM Figure 7 2 Circuit Diagram for Migmatic S400iP...
Page 35: ...OM 287504 Page 29 956172380 A PC5 PC5 PC1 PC8 HD2 HD1...
Page 36: ...OM 287504 Page 30 PC4 PC7 PC2 PC2 FM FM FM FM Figure 7 3 Circuit Diagram for Migmatic S500i...
Page 37: ...OM 287504 Page 31 956172381 A PC1 PC5 PC5 HD1 HD2 PC8...
Page 40: ...Notes Securely connect work clamp to a clean area close to the weld joint Welding Tip...
Page 41: ...Notes...