OM-287504 Page 14
4-4. Installing Gas Supply
Ref. 956172374_10-A / Ref. 149827-B / Ref. 158697-A
CO
2
Gas
Argon Gas Or Mixed Gas
OR
1
2
3
1
2
3
6
4
5
7
8
9
Obtain gas cylinder and chain to
running gear, wall, or other
stationary support so cylinder
cannot fall and break off valve.
1
Cap
2
Cylinder Valve
Remove cap, stand to side of
valve, and open valve slightly. Gas
flow blows dust and dirt from valve.
Close valve.
3
Cylinder
4
Regulator/Flowmeter
Install so face is vertical.
5
Regulator/Flowmeter Gas
Hose Connection
6
Welding Power Source Gas
Hose Connection
Connect supplied gas hose
between regulator/flowmeter gas
hose connection, and fitting on
rear of welding power source.
7
Flow Adjust
Typical flow rate is between 15-20
liters per minute. Check wire
manufacturer’s recommended
flow rate.
8
CO
2
Adapter (Customer
Supplied)
9
O-Ring (Customer Supplied)
Install adapter with O-ring between
regulator/flow meter and CO
2
cylinder.
Tools Needed:
19/32 in (15 mm)
Rear Panel
Summary of Contents for MigMatic S400i
Page 4: ......
Page 5: ......
Page 33: ...OM 287504 Page 27 956172379 A PC5 PC5 HD1 HD2 PC1 PC8...
Page 34: ...OM 287504 Page 28 PC2 PC2 PC4 PC7 FM FM FM FM Figure 7 2 Circuit Diagram for Migmatic S400iP...
Page 35: ...OM 287504 Page 29 956172380 A PC5 PC5 PC1 PC8 HD2 HD1...
Page 36: ...OM 287504 Page 30 PC4 PC7 PC2 PC2 FM FM FM FM Figure 7 3 Circuit Diagram for Migmatic S500i...
Page 37: ...OM 287504 Page 31 956172381 A PC1 PC5 PC5 HD1 HD2 PC8...
Page 40: ...Notes Securely connect work clamp to a clean area close to the weld joint Welding Tip...
Page 41: ...Notes...