OM-251958 Page 34
5-13. Trigger Mode Selection (DX Models Only)
.
Always select a trigger mode.
1
2-t Trigger Mode
When trigger is pressed welding starts.
When trigger is released, welding stops.
2
4-t Trigger Mode
When trigger is pressed, welding starts.
When trigger is released, welding contin-
ues. When trigger is pressed and released
a second time, welding stops.
3
Trigger Mode Selection Button
Press button to select desired trigger mode
and lite corresponding LED.
.
2-t and 4-t trigger methods work in both
manual and synergic modes.
1
2
3
5-14. Welding Wire Diameter Selection For Synergic MIG (DX Models Only)
1
Welding Wire Diameters
2
Welding Wire Diameter
Button
Press button to select desired wire
diameter: 0.6 mm, 0.8 mm, 1.0 mm,
or 1.2 mm, and lite corresponding
LED.
1
2
Summary of Contents for MigMatic 300
Page 21: ...OM 251958 Page 15 Notes...
Page 47: ...OM 251958 Page 41 956142846 B Figure 7 2 Circuit Diagram for Migmatic 300 400 VAC...
Page 48: ...OM 251958 Page 42 956142852 B Figure 7 3 Circuit Diagram for Migmatic 380 230 400 VAC...
Page 49: ...OM 251958 Page 43 956142848 B Figure 7 4 Circuit Diagram for Migmatic 380 400 VAC...
Page 50: ...OM 251958 Page 44 956142851 C Figure 7 5 Circuit Diagram for Migmatic 300 DX 230 400 VAC...
Page 51: ...OM 251958 Page 45 956142847 C Figure 7 6 Circuit Diagram for Migmatic 300 DX 400 VAC...
Page 52: ...OM 251958 Page 46 956142853 C Figure 7 7 Circuit Diagram for Migmatic 380 DX 230 400 VAC...
Page 53: ...OM 251958 Page 47 956142849 C Figure 7 8 Circuit Diagram for Migmatic 380 DX 400 VAC...