![Miller LMSW-52 Owner'S Manual Download Page 19](http://html1.mh-extra.com/html/miller/lmsw-52/lmsw-52_owners-manual_1796165019.webp)
OM-716 Page 15
SECTION 6
−
MAINTENANCE AND TROUBLESHOOTING
6-1. Routine Maintenance
Y
Disconnect power before maintaining.
Every Use
3 Months
6 Months
Inspect
Tips
Replace
Unreadable
Labels
Blow Off
Or
Vacuum
Unit
During Heavy Service,
Clean Monthly
OR
6-2. Overload Protection For 220 Volts Model
Ref. ST-800 233-A / Ref. ST-800 185-A
Y
Turn Off unit and disconnect
input power.
If fuse opens, unit shuts down. To
replace fuse, proceed as follows:
1
Fuse Holder Cover
2
Fuse F1 (See Parts List)
1
2
6-3. Troubleshooting
Trouble
Remedy
No weld output.
Check line fuses, and replace if necessary.
For 220 V models, check fuse F1, and replace if necessary (see Section 6-2).
Low weld output.
Dress or replace tips (see Section 4-1).
Check tip threads. Replace tips if necessary (see Section 4-1).
Remove and clean tongs (see Section 4-2).