![Miller LMSW-52 Owner'S Manual Download Page 18](http://html1.mh-extra.com/html/miller/lmsw-52/lmsw-52_owners-manual_1796165018.webp)
OM-716 Page 14
SECTION 5
−
OPERATION
5-1. Controls (T Models)
ST-146 013-B
1
Spot Weld Timer And Pilot
Light
Weld time adjusts from 0 to 5
seconds. The pilot light turns on
when the weld cycle begins and off
when the cycle ends.
2
Hand Lever
Use lever to open and close tongs.
Close the hand lever during the
welding process to compress the
material between the tips. To adjust
tong pressure, see Section 4-3.
3
Start Switch
Move start switch sideways in ei-
ther direction to start weld cycle.
When weld cycle time ends, or the
start switch is released, weld output
stops, and the timer resets for
another weld cycle.
4
Power Switch
2
3
1
4
5-2. Controls (Non-T Models)
ST-145 104-A
1
Hand Lever
Use lever to open and close tongs.
Close the hand lever during the
welding process to compress the
material between the tips. To adjust
tong pressure, see Section 4-3.
2
Start Switch
Use switch to turn weld current On
and Off. Move switch sideways in
either direction to start weld current.
Release switch to stop weld cur-
rent.
1
2