![Miller LMSW-52 Owner'S Manual Download Page 13](http://html1.mh-extra.com/html/miller/lmsw-52/lmsw-52_owners-manual_1796165013.webp)
OM-716 Page 9
4-2. Installing Or Cleaning Tongs
ST-800 155-A / Ref. ST-800 154-A
Y
Turn off and unplug welder.
.
Be sure tong ends are clean
and not corroded before
installing. Clean tongs with fine
steel wool.
Bottom Tong:
1
Bottom Tong
2
Hole In Spatter Guard
3
Bottom Tong Securing Screws
(4)
Loosen the four screws. If needed,
use a rubber mallet to loosen tong.
Slide tong into bottom tong holder
as far as possible, and position so
that tip is pointing straight up.
Loosely tighten screws.
Top Tong:
4
Top Tong
5
Top Tong Holder/Pivot Casting
6
Top Tong Securing Screws (4)
Loosen the four screws. If needed
for removal, use a rubber mallet to
loosen tong.
Slide tong into pivot casting as far
as necessary, so that tip mates with
bottom tip when tongs are closed.
Loosely tighten screws.
7
Tips
Adjust tong positions to line up cen-
ters of tips as shown. Tighten
screws.
1
2
4
5
6
3
1
4
4
1
7
7
Tools Needed:
3/16 in
9/16 in
Front View
Side View
Tong Alignment
7
Fine
Steel
Wool
Y
OSHA and/or local codes may require addi-
tional guarding to suit the application.