OM-279248 Page 28
6-8. Trigger Select
1
Trigger Select Button
2
Trigger Select LED
Trigger Select function allows the operator to switch between saved welding setups using the welding gun trigger. The operator momentarily
presses and releases the welding gun trigger to switch between Memory 1 or Memory 2.
To enable Trigger Select function, press and release button. Indicator will light. To disable, press and release button. Indicator will not be lit.
1
2
6-9. Preflow
1
Preflow Button
2
Preflow LED
Preflow function allows a timed amount of shielding gas to flow after welding gun trigger is press and before welding arc will be enabled. The
preflow time can be adjusted from 0.1 to 30 seconds.
To enable preflow function, press and release button. Indicator will light. Immediately after enabling, the preflow time will be displayed in the Right
Display. Turn Right Adjust Control (knob below Right Display) to adjust desired preflow time. To disable press and release button. Indicator will
not be lit.
1
2
6-10. Postflow
1
Postflow Button
2
Postflow LED
Postflow function allows a timed amount of shielding gas to flow after the welding operation has ended. The postflow time can be adjusted from
0.1 to 30 seconds.
To enable postflow function, press and release button. Indicator will light. Immediately after enabling, the postflow time will be displayed in the
Right Display. Turn Right Adjust Control to adjust desired postflow time. To disable press and release button. Indicator will not be lit.