OM-266 361 Page 9
SECTION 6 − MAINTENANCE & TROUBLESHOOTING
6-1. Routine Maintenance
!
Disconnect power
before maintaining.
= Check
= Change
= Clean
= Replace
* To be done by Factory Authorized Service Agent
Reference
Every
3
Months
NOTICE − Clean coolant filter. Severe condi-
tions may require more frequent cleaning (con-
tinuous use, high/low temperatures, dirty envi-
ronment, etc.). Failure to properly clean cool-
ant filter voids pump warranty.
Coolant Filter
Every
6
Months
Cracked Parts
Change Coolant (If Using
Water)
Replace Unreadable Labels
Every
12
Months
Change Coolant (If Using (B)050024004)
6-2. Coolant Maintenance
956172138_4-A
!
Turn off welding power source
before maintaining.
1
Cooler Side Panel
2
Coolant Level Indicator
3
Coolant Filter
Unscrew housing to clean filter and
housing.
Changing coolant: Drain coolant by
tipping unit forward. Fill with clean water
and run for 10 minutes. Drain and refill.
If replacing hoses, use hoses
compatible with ethylene glycol,
such as Buna-n, Neoprene, or Hy-
palon. Oxy-acetylene hoses are not
compatible with any product
containing ethylene glycol.
2
1
3
Summary of Contents for hydracool 270 CE
Page 15: ...OM 266 361 Page 11 SECTION 7 ELECTRICAL DIAGRAM 956172139_A...