OM-239026 Page 16
5-6. Connecting Input Power
!
Installation must meet all National
and Local Codes
−
have only
qualified persons make this
installation.
!
Special installation may be
required where gasoline or volatile
liquids are present
−
see NEC Ar-
ticle 511 or CEC Section 20.
1
Receptacle
−
NEMA Type 5-20R
(115 Volt, 20 Amp AC Grounded
Receptacle
−
Customer Supplied)
2
Plug From Unit
A 115 volt AC, 20 amp individual branch
circuit protected by time delay (type D)
fuses or circuit breaker is required.
Select 12 AWG three-conductor extension
cord for distances up to 50 ft (15 m) or 10
AWG three-conductor extension cord for
distances up 100 ft (30 m).
1
2
Ref. Input 6 2011
−
03 245611