![Miller DYNASTY DX Technical Manual Download Page 42](http://html1.mh-extra.com/html/miller/dynasty-dx/dynasty-dx_technical-manual_1796124042.webp)
TM-357 Page 40
Dynasty DX
ST-802 035
Y
Significant DC voltage can
remain on capacitors after
unit is Off. Always check ca-
pacitors as shown to be sure
they have discharged before
working on unit.
Turn Off welding power source and
disconnect input power.
Remove case.
1
Input Capacitor C3
2
Input Capacitor C4
3
Voltmeter
Check input capacitors as shown.
Measure the dc voltage across the
positive (+) and negative (–)
terminals until voltage drops to near
0 (zero) volts.
Proceed with job inside unit.
Reinstall case when finished.
2
Tools Needed:
5/16 in
3
7-5.
Measuring Input Capacitor Voltage
1
3
Summary of Contents for DYNASTY DX