OM-272476 Page 23
7-2.
MIG Remote Welding Mode - GMAW/FCAW Process
!
Weld terminals are energized
through the remote control in MIG
Remote welding mode.
1
Mode Switch
2
Left Display
3
Adjust Control
4
Arc Control
Setup
For typical system connections refer to
Section 7-1.
Rotate Mode Switch to MIG Remote posi-
tion as shown.
The preset voltage is shown in the Left Dis-
play.
Operation
The Adjust Control is used to set desired
preset voltage.
.
The preset voltage can be adjusted re-
motely at the wire feeder if the feeder
has a voltage control. This voltage con-
trol will override the Adjust Control of
preset voltage on the welding power
source. The Remote In Use indicator
will be lit.
Arc Control − Inductance
Inductance control allows the arc charac-
teristics, soft versus stiff, to be changed for
specific applications and wires. The star
setting is good for most applications. Use
soft settings (0−25) to soften the arc and in-
crease puddle fluidity. Use stiff settings
(0−25) to stiffen the arc and reduce puddle
fluidity.
2
4
25.0
263 561-B
1
3