OM-272476 Page 7
SECTION 3 − SPECIFICATIONS
3-1.
Features And Benefits
LVC
t
Line Voltage Compensation is circuitry that keeps the power source output constant regardless of input power fluctuation.
Wind Tunnel Technology
t
circulates air over components that require cooling, not over electronic circuitry, which reduces contaminants and im-
proves reliability in harsh welding environments.
Fan-On-Demand
t
cooling system operates only when needed, reducing noise, energy use and the amount of contaminants pulled through the ma-
chine.
Thermal Overload Protection automatically shuts down the unit, only when necessary to prevent damage to internal components if the duty cycle
is exceeded or air flow and cooling are restricted (see Section 3-7).
Auto Remote Sense enables the unit to automatically sense the connection of a remote control. Operation of the remote control is dependent on the
Mode Switch Setting (see Section 5-2).
Lift-Arc
t
TIG starts provide a contamination free weld without the use of high frequency in the Lift-Arc TIG Welding Mode (see Section 6-3).
Adaptive Hot Start
t
for Stick increases the output amperage at the start of a weld, eliminating electrode sticking in CC and Stick Welding Modes
3-2.
Arc Controls
DIG control allows the arc characteristics, soft versus stiff, to be changed for specific applications and electrodes in Stick Welding Modes (see Sections
8-2 and 8-3).
Inductance control influences the arc stiffness, bead width and appearance, and puddle fluidity in MIG Welding Modes (see Section 7-2).
3-3.
Serial Number And Rating Label Location
The serial number and rating information for this product is located on the rear panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on back cover of this manual.
3-4.
Unit Specifications
.
Do not use information in unit specifications table to determine electrical service requirements. See Sections 4-7 and 4-8 for information on con-
necting input power.
A. Input Voltage And Current At Rated Output
Process
Output Ratings
Amperes Input At Rated
Output (50/60 Hz)
Input Power
(Three Phase)
Current
(Amperes)
Voltage
(DC)
Duty Cycle
(%)
380 VAC
400 VAC
KW
KVA
GTAW (Lift-Arc TIG)
GTAW (TIG)
650
34
100
39.1
37.4
24.2
25.8
750
34
60
45.3
43.2
28.2
29.8
815
34
25
49.4
46.9
30.6
32.5
SMAW (Stick)
650
44
100
49.9
47.4
30.9
32.8
750
44
60
57.9
55.0
35.8
38.2
GMAW/FCAW (Gas)
FCAW-S (No Gas)
SAW (Subarc)
CAC-A (Gouge)
650
44
100
49.9
47.4
30.9
32.8
750
44
60
57.9
55.0
35.8
38.2
815
44
25
63.5
60.2
39.1
41.8
Idle (Fan Off)
N/A
0.32
0.39
0.055
0.21
Idle (Fan On)
0.45
0.53
0.152
0.37
B. Output Range
Process
Output Range
Low Open Circuit Voltage (U
o
)
Rated No-Load Voltage (U
o
) − OCV
GTAW (Lift-Arc TIG)
10A−815A
N/A
12
GTAW (TIG)
10A−815A
12*
63
SMAW (Stick)
30A−815A
12*
65
CAC-A (Gouge)
30A−815A
12*
GMAW/FCAW (Gas)
10V−44V
N/A
FCAW-S (No Gas)
10V−44V
N/A
SAW (Subarc)
10V−65V
N/A
*See Section 5-3 for more information on Optional Low Open Circuit Voltage Mode.